loading
DS/EN IEC 60746-4 - Expression of performance of electrochemical analyzers – Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors
March 4, 2019 - DS

This part of IEC 60746 is intended: - to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; - to establish performance...

CEI EN IEC 60746-4 - Expression of performance of electrochemical analyzers Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors
May 1, 2019 - CEI

This part of IEC 60746 is intended: • to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; • to establish performance...

ASTM D888-05 - Standard Test Methods for Dissolved Oxygen in Water
August 15, 2005 - ASTM International

Dissolved oxygen is required for the survival and growth of many aquatic organisms, including fish. The concentration of dissolved oxygen may also be associated with corrosivity and photosynthetic activity. The absence of oxygen may permit anaerobic decay of...

DS/EN 25814 - Water quality - Determination of dissolved oxygen - Electrochemical probe method
April 30, 2003 - DS

The standard specifies an electrochemical method for the determination of dissolved oxygen in water by means of an electrochemical cell which is isolated from the sample by a gas permeable membrane. The method is suitable for measurements made in the field and for continuous...

IEC 60746-4 - Expression of performance of electrochemical analyzers – Part 4: Dissolved oxygen in water measured by membrane-covered amperometric sensors
December 1, 2018 - IEC

This part of IEC 60746 is intended: • to specify terminology, definitions and requirements for statements by manufacturers for analyzers, sensor units and electronic units used for the determination of dissolved oxygen partial pressure or concentration; • to establish performance...

ASTM D5543-94(2005) - Standard Test Methods for Low-Level Dissolved Oxygen in Water
January 1, 2005 - ASTM International

Dissolved oxygen is detrimental in certain boiler and steam cycles because it may accelerate corrosion. Concentrations above 10 μg/L are unacceptable in many high-pressure boiler systems. The efficiency of dissolved oxygen removal from boiler feedwater by chemical or...

DS/EN 25813 - Water quality - Determination of dissolved oxygen - Iodometric method
April 30, 2003 - DS

This part of the standard specifies an iodometric method for the determination of dissolved oxygen in water by the so-called "Winkler procedure" modified in order to make allowance for certain interferences.

DIN ISO 17289 - Water quality - Determination of dissolved oxygen - Optical sensor method (ISO 17289:2014)
December 1, 2014 - DIN

This International Standard specifies an optical method for the determination of dissolved oxygen in water using a sensor working on the basis of fluorescence quenching. Measurement can be made either as a concentration of oxygen in milligrams per litre, percentage saturation...

UOP364 - TRACE DISSOLVED OXYGEN IN LIQUID
January 1, 1985 - ASTM
A description is not available for this item.
MIL-C-24208 - CHEMICALS, TESTING, DISSOLVED OXYGEN (COLORIMETRIC
NPFC
A description is not available for this item.
DOD-D-24599 - DISSOLVED OXYGEN MEASUREMENT SYSTEM (NAVAL
NPFC
A description is not available for this item.
DOD-K-24674 - KIT, DISSOLVED OXYGEN (METHOD C), NAVAL SHIPBOARD (METRIC)
August 21, 1986 - NPFC

This specification covers a water testing outfit using an organic dye for the determination of dissolved oxygen in feedwater.

DIN EN ISO 5814 - Water quality - Determination of dissolved oxygen - Electrochemical probe method (ISO 5814:2012)
February 1, 2013 - DIN

This International Standard specifies an electrochemical method for the determination of dissolved oxygen in water by means of an electrochemical cell which is isolated from the sample by a gas permeable membrane. Measurement can be made either as a concentration of oxygen in...

ASTM D5543-94(1999)e1 - Standard Test Methods for Low-Level Dissolved Oxygen in Water
June 10, 1999 - ASTM International

1.1 These test methods cover the determination of low-level (∧lt;100 [mu]g/L) dissolved oxygen in thermal-cycle steam condensate, deaerated boiler feedwater, boiler water, and deaerated deionized water. The following test methods are included: Range, mg/L Sections Test Method A--Color...

BS ISO 17289 - Water quality — Determination of dissolved oxygen — Optical sensor method
July 31, 2014 - BSI
A description is not available for this item.
ASTM D888-03 - Standard Test Methods for Dissolved Oxygen in Water
June 10, 2003 - ASTM International

1.1 These test methods cover the determination of dissolved oxygen in water. Two test methods are given as follows: Range, mg/L Sections Test Method A-Titrimetric Procedure-High Level >1.0 8 to 14 Test Method B-Instrumental Probe Procedure 0.05 to 20 15 to 23 1.2 The precision of Test...

BS EN ISO 5814 - Water quality - Determination of dissolved oxygen - Electrochemical probe method
November 30, 2012 - BSI
A description is not available for this item.
ASTM D5462 - Standard Test Method for On-Line Measurement of Low-Level Dissolved Oxygen in Water
June 15, 2013 - ASTM

This test method covers the on-line determination of dissolved oxygen (DO) in water samples primarily in ranges from 0 to 500 μg/L (ppb), although higher ranges may be used for calibration. On-line instrumentation is used for continuous measurements of DO in samples that are brought...

ASTM D5462-13 - Standard Test Method for On-Line Measurement of Low-Level Dissolved Oxygen in Water
June 15, 2013 - ASTM International

1.1 This test method covers the on-line determination of dissolved oxygen (DO) in water samples primarily in ranges from 0 to 500 μg/L (ppb), although higher ranges may be used for calibration. On-line instrumentation is used for continuous measurements of DO in samples that are...

Advertisement