loading
CNS C 4010 - DISTRIBUTION TRANSFORMER
BSMI
A description is not available for this item.
IEEE C57.12.39 - Requirements for Distribution Transformer Tank Pressure Coordination
December 6, 2017 - IEEE

This standard covers certain mechanical requirements for liquid-immersed distribution transformers with respect to tank strength, as well as static and dynamic tank pressure mitigation. This standard can be applied to various tank configurations for distribution...

NEMA TP 3 - Standard for the Labeling of Distribution Transformer Efficiency
January 1, 2000 - NEMA

Defines the labeling of distribution transformers tested to the efficiency levels specified in TP 1. This standard defines the labeling of distribution transformers tested to the efficiency levels specified in TP 1. The label shall be affixed to the transformer in...

CSA C199 - Three-phase network distribution transformers
January 1, 2008 - CSA

This Standard specifies the mechanical and electrical characteristics of three-phase network distribution transformers having rated primary voltages up to 34.5 kV and kV•A ratings of 500 to 2500. Note: It is possible that transformers complying with this Standard will, if...

IEEE C57.12.80 - Terminology for Power and Distribution Transformers
September 30, 2010 - IEEE

This standard is a compilation of terminology and definitions related to electric power and distribution transformers and associated apparatus. It also includes similar terminology relating to power systems and insulation which is commonly involved in transformer technology....

IEEE PC57.12.39 DRAFT - DISTRIBUTION TRANSFORMER TANK PRESSURE COORDINATION
IEEE
A description is not available for this item.
FAA-E-2022 - SUBSTATION, POWER DISTRIBUTION TRANSFORMER, METALC
DOT
A description is not available for this item.
CSA C301.1 - Single-phase submersible distribution transformers
January 1, 2006 - CSA

This Standard covers the features of single-phase submersible transformers rated 25 to 333 kV•A. Note: For details not covered herein, reference should be made to CSA C2.1. This Standard applies only to single-phase distribution transformer units intended for use in a...

CSA C301.2 - Three-phase submersible distribution transformers
January 1, 2006 - CSA

This Standard covers the features of three-phase submersible transformers rated 75 to 3000 kV•A. Note: For details not covered herein, reference should be made to CSA C2.1. This Standard applies only to three-phase distribution transformer units intended for use in a ventilated...

IEEE C57.12.37 - The Electronic Reporting of Distribution Transformer Test Data
September 3, 2015 - IEEE

This standard provides a basis for electronic reporting of transformer test data on liquid-immersed distribution transformers. This standard defines how to format and report the standard test data when electronic reporting is specified. In addition, it defines an extended set...

Power and Distribution Transformers Practical Design Guide
February 12, 2021 - CRC

This book is based on the author's 50+ years experience in the power and distribution transformer industry. The first few chapters of the book provide a step-by-step procedures of transformer design. Engineers without prior knowledge or exposure to design can follow the...

IEEE C57.138 - Recommended Practice for Routine Impulse Tests for Distribution Transformers
December 7, 2016 - IEEE

This recommended practice covers routine impulse tests performed on distribution transformers, as required in IEEE Std C57.12.00™, and described in 10.4 of IEEE Std C57.12.90™-20151. Distribution transformers covered by this recommended practice are liquid-immersed,...

NEMA TP 1 - Guide for Determining Energy Efficiency for Distribution Transformers
January 1, 2002 - NEMA

This standard is intended for use as a basis for determining the energy efficiency performance of the equipment covered and to assist in the proper selection of such equipment. This standard covers single-phase and three-phase dry-type and liquid-filled distribution transformers....

IEEE C57.12.35 - Bar Coding for Distribution Transformers and Step-Voltage Regulators
August 23, 2013 - IEEE

This standard sets forth bar-code label requirements for overhead, pad-mounted, and underground-type distribution transformers and step-voltage regulators. Included herein are requirements for data content, symbology, label layout, print quality, and label life expectancy. This...

CSA C802.1 - Minimum efficiency values for liquid-filled distribution transformers
January 1, 2013 - CSA

This Standard specifies energy efficiencies for liquid-filled distribution transformers. The total ownership cost (TOC) methodology is recommended as the means for achieving these energy efficiencies, particularly for use by electric utilities. This Standard also specifies an optimal...

CSA C2.1 - Single-phase and three-phase liquid-filled distribution transformers
January 1, 2006 - CSA

This Standard specifies the requirements for distribution transformers with the exception of those distribution transformers that are covered by CSA C2.2, C227.3, and C227.4. Note: The operation of transformers complying with this Standard by other than an...

CSA C2.2 - Pole-mounted, single-phase distribution transformers for electric utilities
January 1, 2006 - CSA

This Standard specifies the requirements for distribution transformers intended primarily for operation by electric utilities. Note: The operation of transformers complying with this Standard by other than an electric utility can be subject to additional requirements by the...

JIS C 4304 - 6kV Oil-immersed distribution transformers
May 20, 2013 - JSA
A description is not available for this item.
JIS C 4306 - 6kV Encapsulated-winding distribution transformers
May 20, 2013 - JSA
A description is not available for this item.
IEEE 1265 - BAR CODING FOR DISTRIBUTION TRANSFORMERS
IEEE
A description is not available for this item.
Advertisement