Fireplace Accessories UL 907 1.1 These requirements apply to fireplace accessories that are intended only for field installation into or attachment to existing masonry fireplaces. Fireplace accessories include items such as heat exchangers, glass door assemblies, and the like. For the...
1.1 These requirements cover the following devices intended for installation and operation on horizontal and vertically opening hoistway doors and gates and car doors and gates in accordance with the requirements of ASME A17.1/CSA B44: a) Hoistway Door Interlocks; b) Hoistway...
1.1 This specification specifies requirements for ballistic-resistant panels to be mounted in or on public safety vehicle doors to protect against complete penetration of projectiles from small arms.2 1.2 The purpose of this specification is to define minimum performance for...
1.1 These test methods determine the ability of sliding door assemblies to restrain, delay, or frustrate forced entry. 1.2 For purposes of these test methods, sliding door assemblies are defined as described in 1.2.1 - 1.2.4 and as shown in Fig. 1. Sliding door assemblies with...
This SAE Aerospace Recommended Practice (ARP) applies to landing gear structures and mechanisms (excluding wheels, tires, and brakes and other landing gear systems) for all types and models of civil and military aircraft. All axles, wheel forks, links, arms, mechanical and gas/oil shock struts,...
This specification establishes the requirements for a polysulfide sealing compound in putty consistency to be used for form-in-place sealing of removable doors, skins, and panels.
This specification covers steel expanded-metal doors suitable for installation in expanded-metal bulkheads, structural bulkheads, and structural arches. Expanded-metal doors are furnished in four types: Type I (right hand), Type II (left hand), Type III (right hand reverse) and Type...
1.1 This specification covers the construction of standard and custom-built interior steel doors and frames for ships including U.S. Coast Guard certificated vessels with domestic routes. 1.2 Doors and frames are to be hollow metal construction with the door insulated for sound...
1.1 These test methods cover door assemblies of various materials and types of construction for use in wall openings to deter unwanted intruders. 1.2 Door assemblies, covered by these test methods, also include individual components such as the hinge, lock, door, strike, and...
This specification covers the minimum requirements for and the methods of application of gypsum sheathing for use as a substrate for exterior wall cladding. Gypsum sheathing board is a substrate that shall be covered by an exterior cladding or other weather-resistive barrier and is not intended for...
1.1 This test method covers out-of-doors exposure testing of finishes that are normally field-applied to thermal insulation and possibly include joints or joint sealants, or both. Such exposure is essential prior to the determination of certain physical properties when the finish is to be...
1.1 This specification covers exterior windows, glazed curtain walls, doors, and impact protective systems used in buildings located in geographic regions that are prone to hurricanes. 1.1.1 Exception-Exterior garage doors and rolling doors are governed by ANSI/DASMA 115 and...
1.1 This specification, to be used in conjunction with Specification F1073, covers the principal dimensions and the mechanical requirements for manufacturing steel and aluminum individually dogged, airtight/gastight double doors for personnel access through bulkheads, complete with frames,...
5.1 The fan pressurization procedure provides a relatively fast evaluation of the airtightness of building envelopes. In order for the accuracy of the test results to be known, the airflow rate measurement technique of the fan pressurization system must be calibrated. 5.2 This test method is...
1.1 This consumer safety performance specification establishes performance requirements, test methods, and labeling requirements for motorized partitions. 1.2 Motorized partitions are used to provide flexibility in the size of spaces typically used for meetings, sports, recreational areas, schools,...
1.1 This test method sets forth the requirements and testing procedures to test forced-entry-resista