5.1 This test method demonstrates conformity of a dynamic mechanical analyzer at an isothermal temperature of 21 °C. 5.2 Dynamic mechanical analysis experiments often use linear temperature change. This test method does not address the effect of that change in temperature on the loss...
5.1 Dynamic mechanical analysis monitors changes in the viscoelastic properties (that is, storage modulus, loss modulus, tangent angle delta) of a material as a function of temperature and frequency, providing a means to quantify these changes. In many cases, the value to be assigned is the...
1.1 This test method covers the measurement of dynamic viscosity and derivation of kinematic viscosity of liquids, such as new and in-service lubricating oils, by means of an oscillating piston viscometer. 1.2 This test method is applicable to Newtonian and non-Newtonian liquids; however the...
1.1 This test method specifies a procedure for the determination of the kinematic viscosity, ?, of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The dynamic...
1.1 This test method covers the measurement of dynamic viscosity and density for the purpose of derivation of kinematic viscosity of petroleum liquids, both transparent and opaque. The kinematic viscosity, ?, in this test method is derived by dividing the dynamic viscosity, ?, by the...
1.1 This test method covers the determination of the dynamic elastic properties of advanced ceramics. Specimens of these materials possess specific mechanical resonant frequencies that are determined by the elastic modulus, mass, and geometry of the test specimen. Therefore, the...
1.1 This test method covers determination of the dynamic elastic properties of advanced ceramics at ambient temperatures. Specimens of these materials possess specific mechanical resonant frequencies that are determined by the elastic modulus, mass, and geometry of the test specimen. The...
This specification establishes the requirements for four classes of machinable, high-density tungsten base metal produced by consolidating metal powder mixtures, the composition of which is mainly tungsten. This material specification may be used for bare parts or for parts that may be coated with...
1.1 This test method covers the determination of parameters calculated from the measurement of modulus (G*) and phase angle (d) of asphalt binders when tested in dynamic (oscillatory) shear using parallel plate geometry in accordance with Test Method D7175. These parameters are considered...
1.1 This practice covers bactericidal claims for non-food-contact antimicrobial surfaces. 1.2 This practice is applicable to a wide range of surfaces, including nonporous, semi-porous, and hydrophobic surfaces. 1.3 This practice is also applicable for determining the efficacy of additives...
1.1 This test method covers the determination of slow crack growth (SCG) parameters of advanced ceramics by using constant stress rate rectangular beam flexural testing, ring-on-ring biaxial disk flexural testing, or direct tensile strength, in which strength is determined as a function of applied...
1.1 This test method covers the determination of asphalt binder peak stress (tf), peak stress energy (Ef), and peak strain (?f) using the monotonic shear strength (MOSS) test. tf, Ef, and ?f can be used to measure the strength, toughness, and strain tolerance of an asphalt binder under constant...
5.1 This test method is used to measure viscoelastic properties through the strain softening effects of a strain amplitude sweep (the Payne Effect). 5.2 For the uncured state, the time conditioning and strain amplitude strain sweeps can relate to colloidal silica particle or carbon black...
1.1 This test method assesses metal or other ions released from single-use, metallic, implantable medical devices or components thereof by exposing the device to solutions simulating the in vivo environment and temperature in a container for a predetermined time frame with regular sampling at...
1.1 This test method covers the determination of slow crack growth (SCG) parameters of advanced ceramics by using constant stress-rate flexural testing in which flexural strength is determined as a function of applied stress rate in a given environment at elevated temperatures. The strength...
4.1 This test method applies to the measurement of SE of planar materials under normal incidence, far-field, plane-wave conditions (E and H tangential to the surface of the material). 4.2 The uncertainty of the measured SE values is a function of material, mismatches throughout the transmission...
5.1 This practice establishes the basic structure for education in the characterization of nanoscale materials at the undergraduate college level. The approach taken is to classify specific characterization methods into two tiers, with a minimum number of methods to be selected from each tier and...
5.1 The purpose of this guide is to provide a basic educational structure for pattern generation in nanotechnology to organizations developing or carrying out education programs for the nanotechnology workforce. This guide helps to describe the minimum knowledge base for anyone involved in...
5.1 This guide is to provide, at the undergraduate college level, a basic educational structure in the health and safety aspects of nanotechnology to organizations developing or carrying out education programs for the nanotechnology workforce. This guide helps to describe the minimum knowledge base...