4.1 UV-A lamps are used in fluorescent penetrant and magnetic particle examination processes to excite fluorophores (dyes or pigments) to maximize the contrast and detection of discontinuities. The fluorescent dyes/pigments absorb energy from the UV-A radiation and re-emit visible...
4.1 UV-A lamps are used in fluorescent penetrant and magnetic particle examination processes to excite fluorophores (dyes or pigments) to maximize the contrast and detection of discontinuities. The fluorescent dyes/pigments absorb energy from the UV-A radiation and re-emit visible...
1.1 This practice covers procedures for water-washable fluorescent penetrant testing of materials. It is a nondestructive testing method for detecting discontinuities that are open to the surface such as cracks, seams, laps, cold shuts, laminations, isolated porosity, through leaks, or lack...
1.1 This practice covers specific procedures and test conditions for performing ultraviolet conditioning exposures on photovoltaic modules or mini-modules using fluorescent ultraviolet lamps in accordance with Practices G151 and G154. This practice covers test conditions that meet the...
5.1 The determination of the total volume?percent of saturates, olefins, and aromatics in petroleum fractions is important in characterizing the quality of petroleum fractions as gasoline blending components and as feeds to catalytic reforming processes. This information is also important in...
5.1 This test method is based on Test Method F903 for measuring resistance of chemical protective clothing materials to penetration by liquids. This test method is normally used to evaluate specimens from individual finished items of protective clothing and individual samples of materials that are...
1.1 This practice covers specific procedures and test conditions that are applicable for a fluorescent UV lamp and water apparatus exposure of plastics conducted in accordance with Practices G151 and G154. This practice also covers the preparation of test specimens, the test conditions best...
1.1 This practice establishes minimum requirements for magnetic particle testing used for the detection of surface or slightly subsurface discontinuities in ferromagnetic material. This practice is intended for aerospace applications using the wet fluorescent method. Refer to Practice...
1.1 This practice covers general procedures to be used when exposing materials in accelerated test devices that use laboratory light sources. Detailed information regarding procedures to be used for specific devices are found in standards describing the particular device being used. For example,...
1.1 This practice applies to the instrumental color measurement of fluorescent specimens excited by near ultraviolet and visible radiation that results in fluorescent emission within the visible range. It is not intended for other types of photoluminescent materials such as...
This specification covers a rigid wall, nonexpendable shelter constructed of aluminum-faced, nonmetallic honeycomb sandwich panels. Electrical continuity testing, water leakage and operational testing, performance testing, paint adhesion testing, packaging examination, thermal shock test, panel...
4.1 This test method describes the procedure to evaluate or compare, or both, the durability of sealants when subjected to accelerated weathering and cyclic movement in a joint. 4.2 Sealant installation procedures, design considerations and movement during cure affect the aging processes and are...
5.1 The determination of the total volume?percent of saturates, olefins, and aromatics in petroleum fractions is important in characterizing the quality of petroleum fractions as gasoline blending components and as feeds to catalytic reforming processes. This information is also important in...
1.1 This test method covers techniques to evaluate the surface discoloration of white or light-colored vulcanized rubber that may occur when subjected to accelerated weathering exposures in fluorescent UV and xenon arc apparatus. 1.2 This test method also describes how to qualitatively...
1.1 This practice provides guidelines for the instrumental transmittance measurement of the color of coated and uncoated transparent glass. (See Terminology E284.) 1.2 The practice specifically excludes fluorescent and iridescent samples. 1.3 The values stated in SI units are to be regarded...
1.1 This practice provides guidelines for the instrumental reflectance measurement of the color of flat, coated and uncoated glass. (See Terminology E284.) 1.2 The practice specifically excludes fluorescent and iridescent samples. 1.3 The values stated in SI units are to be regarded as...
1.1 This practice covers the basic principles and operating procedures for using fluorescent light to determine color stability of plastics when materials are exposed in typical office environments where fluorescent overhead lighting and window-filtered daylight are used for...
1.1 This standard describes procedures for the determination of the relative lightfastness and weatherability of printed matter under the following conditions, which involve exposure to natural daylight or accelerated procedures in the laboratory: 1.1.1 Method 1-Daylight behind window glass, 1.1.2...
This test method provides a uniform procedure for radiographic examination of weldments using industrial radiographic film. Requirements expressed in this method are intended to control the quality of the radiographic images and are not intended for controlling acceptability or quality of welds....
5.1 Rubber in contact with light colored organic finishes may stain the surfaces in contact with the rubber (contact staining) and surfaces adjacent to or beyond the rubber (migration staining), especially under conditions of heat, pressure, or sunlight. When a light colored rubber veneer or...
Narrow Your Results