1.1 This test method covers the determination of total oil and grease (TOG) that can be extracted from water or wastewater samples by cyclohexane and measured by non-dispersive IR spectroscopy from 1370?cm-1 to 1380?cm-1. Treating the extract with Florisil to remove polar substances prior to...
5.1 These test methods are applicable to greases of National Lubricating Grease Institute (NLGI) consistency numbers 0 to 4 and are intended for use only where the size of the sample prevents the use of Test Methods D217. 5.2 Actual reduced-scale penetration values are not used or...
1.1 This test method covers the determination of evaporation loss of lubricating greases at temperatures between 93?°C and 316?°C (200?°F and 600?°F). 1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.3 This standard...
1.1 This test method covers measurement, in poises, of the apparent viscosity of lubricating greases in the temperature range from -54?°C to 38?°C (-65?°F to 100?°F). Measurements are limited to the range from 25?P to 100?000?P at 0.1?s-1 and 1?P to 100?P at 15?000?s-1. Note 1: At very low...
5.1 This test method, used for specification purposes, differentiates between lubricating greases having low, medium, and high level of extreme-pressure properties. The results do not necessarily correlate with results from service. 5.2 It is noted that lubricating greases that have...
1.1 This test method covers the determination of the load-carrying capacity of lubricating greases by means of the Timken Extreme Pressure Tester. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard...
1.1 This test method covers the evaluation of the performance of lubricating greases in ball bearings operating under light loads at high speeds and elevated temperatures. 1.2 The values stated in SI units are to be regarded as standard. 1.2.1 Exception-The values given in parentheses are...
This specification covers silver-indium-cadmiu
This practice covers a cleaning and de-scaling procedure useful to producers, users, and fabricators of zirconium and zirconium alloys for the removal of ordinary shop soils, oxides, and scales resulting from heat treatment operations and foreign substances present as surface contaminants....
This specification covers filled epoxy-coated seven-wire prestressing steel strands with protective fusion-bonded epoxy coating applied by the electrostatic deposition method. This specification also covers relaxation loss limits for filled epoxy coated strands. Prestressing steel strands shall be...
1.1 This test method covers a procedure for the detection and estimation of deleterious particles in lubricating grease. 1.2 This test method is applicable to all lubricating greases. It can also be used to test other semi-solid or viscous materials. Grease fillers, such as...
1.1 This practice covers the necessary preparations and planning for the conduct of interlaboratory programs for the development of estimates of precision (determinability, repeatability, and reproducibility) and of bias (absolute and relative), and further presents the standard phraseology for...
5.1 This test method can be used to determine wear properties and coefficient of friction of lubricating greases at selected temperatures and loads specified for use in applications where high-speed vibrational or start-stop motions are present for extended periods of time under initial high...
1.1 This test method determines resistance of lubricating greases to oxidation when stored statically in an oxygen atmosphere in a sealed system at an elevated temperature under conditions of test. 1.2 The values stated in SI units are to be regarded as standard. No other units of...
1.1 This practice covers the procedure for use of microwave radiation for sample decomposition prior to elemental determination by atomic spectroscopy. 1.1.1 Although this practice is based on the use of inductively coupled plasma atomic emission spectrometry (ICP-AES) and atomic absorption...
1.1 This test method can be used to determine the grease particle capture efficiency of components and systems used in commercial kitchens to capture grease effluent prior to entering the exhaust duct. The results can be used to select a filter system best suited to a particular...
1.1 This test method determines resistance of lubricating greases to oxidation when stored statically in an oxygen atmosphere in a sealed system at an elevated temperature under conditions of test. 1.2 The values stated in SI units are to be regarded as standard. No other units of...
1.1 This test method covers the determination of the load-carrying properties of lubricating fluids. The following two determinations are made: 1.1.1 Load-wear index (formerly Mean-Hertz load). 1.1.2 Weld point by means of the four-ball extreme-pressure (EP) tester. 1.2 For the determination of the...
1.1 This test method covers a procedure for making a preliminary evaluation of the anti-wear properties of fluid lubricants in sliding contact by means of the Four-Ball Wear Test Machine. Evaluation of lubricating grease using the same machine is detailed in Test Method D2266. 1.2 The values...
5.1 It is known that contamination by water can affect the shear stability of some greases in service. This test method is widely used to determine the wet shear stability of greases in service. Many grease specifications require these procedures as a wet shear stability test....