Dimensions and characteristics of tungsten-halogen lamps used for projection, photographic, flood lighting, airfield and general purposes.
This standard specifies performance requirements for various single-ended, doubleended, integral reflector, and PAR tungsten halogen lamps, with rated voltages up to 277V, and used for projection, photographic, (floodlight), special purpose, general lighting service (GLS), and...
This Notice applies to all quartz halogen lamps used in lineside signals, route and junction indicators, and banner signals. Purpose This Notice directs that quartz halogen lamps be run at the rated voltage and that new lamps, when fitted, are checked for correct...
This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic...
This SAE Aerospace Recommended Practice (ARP) provides the qualification test procedure requirements for low wattage halogen lamps (less than 35 watts) intended for use primarily in aircraft applications. The purpose of these tests is to provide a laboratory means of determining the...
This standard defines the dimensional limits and other physical characteristics required to ensure interchangeability and assist in the proper application of a specific category of lamps. This category is tungsten-halogen lamps with G22 bases and 63.5 mm (2½ in.) nominal light...
This SIN applies to all 50W Level Crossing Road Traffic Lights (Wig-Wags) to BR908: April 1991 and all 50W, 24V (086/022951) type lamps in the supply chain. Purpose This Special Inspection Notice is being issued to replace all 50W Quartz Halogen lamps fitted to Level Crossing...
This TI applies to all Bombardier fibre optic signals & indicators that utilise the Philips 12V, 50W quartz halogen matrix signalling lamp. Purpose This TI is being issued to address a failure mode associated with the type of lamp used in Bombardier fibre optic signals &...
This standard consolidates projection lamps with G5.3 bases into a single standard. The lamps contained in this standard are not to be considered as interchangeable, although physically they will all fit the common G5.3 lampholders. The photometry of each lamp is dependent upon...
This part of IEC 60432 specifies the safety requirements for single-capped and doublecapped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: - projection (including cinematograph and still projection), - photographic (including...
This part of IEC 60432 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: - projection (including cinematograph and still projection), - photographic (including...
This part of IEC 60432 specifies the safety requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: • projection (including cinematograph and still projection), • photographic (including...
This part of IEC 62442 defines a measurement method for the power losses of electromagnetic transformers as well as the power losses and the standby power of electronic convertors for tungsten-halogen lamps and for LED light source(s). It is applicable for controlgear that are...
This part of IEC 62442 defines a measurement method for the power losses of electromagnetic transformers as well as the power losses and the standby power of electronic convertors for tungsten-halogen lamps and for LED light source(s). It is applicable for controlgear that are...
Narrow Your Results