1.1 This test method covers the determination by means of a glass hydrometer in conjunction with a series of calculations of the API gravity of crude petroleum and petroleum products normally handled as liquids and having a Reid vapor pressure (Test Method D323) of 14.696 psi (101.325?kPa)...
1.1 This test method covers the determination of the density or relative density of light hydrocarbons including liquefied petroleum gases (LPG) having Reid vapor pressures exceeding 101.325?kPa (14.696?psi). 1.2 The prescribed apparatus should not be used for materials having vapor pressures...
1.1 This test method covers the determination of the density or relative density of light hydrocarbons including liquefied petroleum gases (LPG) having Reid vapor pressures exceeding 101.325?kPa (14.696?psi). 1.2 The prescribed apparatus should not be used for materials having vapor pressures...
4.1 The relative density of an engine coolant may be used to determine the approximate percent glycol, freezing point, and boiling point, provided the glycol type is known. 4.2 The relative density of an engine coolant concentrate can be used as a production control test. 4.3 ASTM specifications...
1.1 X-Ray diffraction (XRD) is a tool for identifying minerals, such as quartz and feldspar, and types of clay present in bulk samples of equine surfaces. Determining the mineralogy of a given bulk sample provides insight into surface properties, such as abrasion resistance by comparing the...
This specification covers mixing water used in the production of hydraulic cement concrete. It defines sources of water and provides requirements and testing frequencies for qualifying individual or combined water sources. Mixing water shall consist of: batch water, ice, water added by truck...
1.1 This test method covers the quantitative determination of the distribution of particle sizes of the fine-grained portion of soils. The sedimentation by hydrometer method is used to determine the particle-size distribution (gradation) of the material that is finer than the No. 200 (75-µm)...
1.1 This test method covers the quantitative determination of the distribution of particle sizes of the fine-grained portion of soils. The sedimentation by hydrometer method is used to determine the particle-size distribution (gradation) of the material that is finer than the No. 200 (75-µm)...
1.1 Two test methods are provided to give a qualitative indication of the natural dispersive characteristics of clayey soils: Method A and Method B. 1.1.1 Method A-Procedure for Natural Soil Crumbs described in 10.1. 1.1.2 Method B-Procedure for Remolded Soil Crumbs described in 10.2. 1.2 The crumb...
1.1 This test method covers the determination by means of a glass hydrometer in conjunction with a series of calculations of the API gravity of crude petroleum and petroleum products normally handled as liquids and having a Reid vapor pressure (Test Method D323) of 101.325 kPa (14.696 psi)...
Abstract: Specifications, guides, and test methods cover sensory evaluation, language services and products, liquid-in-glass, thermometers and hydrometers, thermocouples, medical thermometry, radiation thermometry, and resistance thermometers.
This specification establishes the properties and test methods for aqueous dispersions of polytetrafluoroethyl
This test method covers the determination of the relative density of glycols, glycerin, heat transfer fluids, engine coolant concentrates, and aqueous engine coolants. The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for...
4.1 The relative density of an engine coolant may be used to determine the approximate percent glycol, freezing point, and boiling point, provided the glycol type is known. 4.2 The relative density of an engine coolant concentrate can be used as a production control test. 4.3 ASTM specifications...
Two test methods are provided to give a qualitative indication of the natural dispersive characteristics of clayey soils: Method A and Method B. Method A-Procedure for Natural Soil Crumbs described in 10.1. Method B-Procedure for Remolded Soil Crumbs described in 10.2. The crumb test, while a good,...
1.1 Two test methods are provided to give a qualitative indication of the natural dispersive characteristics of clayey soils: Method A and Method B. 1.1.1 Method A-Procedure for Natural Soil Crumbs described in 10.1. 1.1.2 Method B-Procedure for Remolded Soil Crumbs described in 10.2. 1.2 The crumb...
1.1 These test methods cover the determination of the specific gravity of halogenated organic solvents and solvent admixtures. They define suitable apparatus and procedures and furnish details underlying the interpretation of test data and the selection of numerical limits for agreement among...
This specification covers glass hydrometers of various scale graduation systems, as required by the ASTM test methods in which they are used. Hydrometers shall be of the constant-mass, variable-displacemen
This test method describes the principles, apparatus, and procedures for the inspection, calibration, and verification of ASTM glass hydrometers. This test method is applicable to ASTM hydrometers and may be used for other general hydrometers of the constant-mass,...
1.1 This test method describes the principles, apparatus, and procedures for the inspection, calibration, and verification of ASTM glass hydrometers. This test method is applicable to ASTM hydrometers and may be used for other general hydrometers of the constant-mass,...