loading
APA A750 - Builder Tips: I-Joist Blocking
April 1, 2009 - APA

Explains why I-joists benefit from being installed with blocking, blocking material composition, and installation details

APA TT-094 - Technical Topics: Rim Board and I-Joist Nail Spacing Recommendations
April 1, 2010 - APA

Complete Title: Technical Topics: Nail Spacing Recommendations for APA EWS Rim Boards® and I-Joists

APA E715 CANADA - I-Joist Construction Details - Canadian Limit States Design
March 1, 2008 - APA

Installation guide includes recommended construction details for I-joists in floor and roof applications. Also includes details for cantilevers and web holes

APA X720 - PRI-400 Performance Standard for APA EWS I-Joists
May 1, 2012 - APA

The APA EWS Performance-Rated I-joist is an "I"-shaped prefabricated structural member using solid-sawn lumber or structural composite lumber flanges and structural-use panel webs bonded together with exterior adhesives. To be classified as an APA EWS Performance-Rated...

APA PRI-405 - Performance Standard for APA EWS Commercial I-Joists
December 1, 2012 - APA

The APA EWS Performance-Rated I-joist is an "I" -shaped prefabricated structural member using sawn or structural composite lumber flanges and structural-use panel webs boded together with exterior adhesives. This standard provides design properties for APA EWS Performance-Rated...

APA A755 - Builder Tips: I-Joist Squash Blocks
February 1, 2013 - APA
A description is not available for this item.
APA A760 - Builder Tips: I-Joist Filler Blocks
November 1, 2010 - APA
A description is not available for this item.
APA A765 - Builder Tips: I-Joist Backer Blocks
November 1, 2010 - APA
A description is not available for this item.
APA A745 - Builder Tips: I-Joist Web Stiffeners
November 1, 2010 - APA
A description is not available for this item.
APA Y315 - Specification Guide: Short Form for I-Joists and Rim Board
August 1, 2009 - APA

Sample specifications for APA Performance Rated I-Joists and Rim Boards.

APA E720 CANADA - PRI-400 Performance Standard for APA EWS I-Joists (Limit States Design)
November 1, 2013 - APA

The APA EWS Performance-Rated I-joist is an "I"-shaped prefabricated structural member using solid-sawn lumber or structural composite lumber flanges and structural-use panel webs bonded together with exterior adhesives. To be classified as an APA EWS Performance-Rated...

APA Z725 - APA Performance Rated I-Joists
January 1, 2012 - APA
A description is not available for this item.
APA Z705 - Technical Note - Stairwell Opening in APA PRI I-Joist Floors
September 1, 2012 - APA
A description is not available for this item.
APA EWS S400 - APA Glulam, I-joist and LVL Publication Index
November 1, 2006 - APA

A supplement to the APA Publication Index. Formerly referred to as APA EWS Publications Index

APA E705 - Technical Note: Proper Storage and Handling of I-Joists and LVL
March 1, 2005 - APA

Provides recommendations for safe handling and storage of I-joists and LVL. Best practices for cut-up at distribution and moisture effects are also discussed.

APA J745 - Technical Note: Sprinkler Pipe Installation for APA Performance Rated I-Joists
June 1, 2009 - APA

APA Performance Rated wood I-joists (PRI) are often used in conjunction with both steel and chlorinated polyvinyl chloride (CPVC) sprinkler systems. This PDF package includes a Technical Note providing basic guidance on appropriate methods of attachment of steel and CPVC sprinkler...

ASTM D5055-04 - Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists
April 1, 2004 - ASTM International

1.1 GeneralThis specification gives procedures for establishing, monitoring, and reevaluating structural capacities of prefabricated wood I-joists. Capacities considered are shear, moment, and stiffness. Procedures for establishing common details are given and certain design...

ASTM D5055-03 - Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists
October 1, 2003 - ASTM International

1.1 General-This specification gives procedures for establishing, monitoring, and reevaluating structural capacities of prefabricated wood I-joists. Capacities considered are shear, moment, and stiffness. Procedures for establishing common details are given and certain design...

ASTM D5055-02 - Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists
October 10, 2000 - ASTM International

1.1 General-This specification gives procedures for establishing, monitoring, and reevaluating structural capacities of prefabricated wood I-joists. Capacities considered are shear, moment, and stiffness. Procedures for establishing common details are given and certain design...

ASTM D5055-00a - Standard Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists
October 10, 2000 - ASTM International

1.1 General-This specification gives procedures for establishing, monitoring, and reevaluating structural capacities of prefabricated wood I-joists. Capacities considered are shear, moment, and stiffness. Procedures for establishing common details are given and certain design...

Advertisement