1.1 This specification describes a data file exchange format for three-dimensional (3D) imaging data, known as the ASTM E57 3D file format, Version 1.0. The term "E57 file" will be used as shorthand for "ASTM E57 3D file format" hereafter. 1.2 An E57 file is capable of storing 3D point data,...
1.1 This practice details the procedure for determining the low-contrast visual acuity of a radiographic interpreter by evaluating the ability of the individual to detect linear images of varying radiographic noise, contrast, and sharpness. No statement is made regarding the applicability of...
1.1 These digital reference images illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The digital reference images are an adjunct to this document and must be purchased separately from ASTM International if...
1.1 This guide covers the most common questions about reference radiographs and digital reference images and their use. Reference radiographs and digital reference images are used throughout industry to create acceptance specifications by identifying, categorizing, and grading...
1.1 This document describes the appearance of a radiographic image where fundamental components of image quality are changed, that is, variables such as whether an X-ray or gamma ray source was used, the characteristics of the radiographic film (gradient, granularity, and developing...
1.1 This standard extends the application of steel casting Reference Radiographs E446, E186, and E280 when performing film radiography and Digital Reference Images E2868 and E3030 when performing digital radiography to ductile iron castings when determined appropriate for specific...
1.1 This practice covers instruction for determining the density calibration of X- and ?-ray computed tomography (CT) systems and for using this information to measure different material densities from CT images. The calibration is based on an examination of the CT image of a disk of...
1.1 This guide to obtainable equivalent penetrameter sensitivity covers the minimum penetrameter thicknesses for which the image of the 1T and 2T holes is visible for a few practical radiographic conditions using industrial X-ray film. The values represent near optimum sensitivity for flat...
1.1 The reference radiographs provided in the adjunct to this standard illustrate various types and degrees of discontinuities occurring in thin-wall steel investment castings. Use of this standard for the specification or grading of castings requires procurement of the adjunct reference...
4.1 Personnel utilizing reference radiographs to this standard shall be qualified and authorized to perform radiographic interpretation in accordance with a nationally or internationally recognized NDT personnel qualification practice or standard such as ANSI/ASNT-CP-189, SNT-TC-1A, NAS 410, ISO...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses of 2?in. to less than 41/2 in. (50.8?mm to 114 mm). The reference radiograph films are an adjunct to this document and must be...
1.1 This specification covers flexible, non-exposed glass-bead lens and microprismatic, retroreflective sheeting designed for use on traffic control signs, delineators, barricades, and other devices. This specification does not address inks, overlays, or other imaging methods that may be...
5.1 Visual interpretation of gear teeth condition, such as contact patterns, scuffing, and wear, differs from examination for surface-breaking cracks or early signs of macro-pitting. Guidance for visual interpretation of gear tooth condition is provided in ASNI/AGMA 1010-F14. 5.2 Eddy current array...
1.1 The reference radiographs provided in the adjunct to this standard are reproductions of original radiographs and are supplied as a means for establishing some of the categories and severity levels of discontinuities in titanium castings that may be revealed by radiographic examination. Use of...
1.1 This standard provides reference radiographs for steel fusion welds that contain typical discontinuities with varying severity levels in different thicknesses of material. The reference radiograph films are an adjunct to this standard and must be purchased separately from ASTM International if...
1.1 These reference radiographs for gray iron castings consist of one set of illustrations of centerline shrinkage with severity levels 1 to 5 using three radiation source types as follows: 1.1.1 Volume I: Medium Voltage (Nominal 250 kVp) X-ray Reference Radiographs-Set of 5 severity levels in a...
4.1 Laser profiling assessment is a quality control tool for identifying and quantifying deformation, physical damage, and other pipe anomalies after installation, providing means and methods for determining the quality of workmanship and compliance with project specifications. Laser profiling can...
1.1 This practice covers the procedure for the post installation verification and acceptance of buried pipe deformation using a visible rotating laser light diode(s), a pipeline and conduit inspection analog or digital CCTV camera system and image processing software. The combination CCTV...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses up to 2 in. (50.8 mm) (see Note 2). The reference radiograph films are an adjunct to this standard and must be purchased separately...
1.1 This test method defines an empirical technique for the measurement of the effective collimation ratio, L/D, of neutron radiography beams. The technique is based upon analysis of a neutron radiographic image and is independent of measurements and calculations based on physical dimensions...