1.1 These test methods cover procedures for testing rigid electrical insulation normally manufactured in flat sheet or plate form. They are generally used as terminal boards, spacers, voltage barriers, and circuit boards. 1.2 Use Test Methods D619 (withdrawn) or Specification D710 for tests...
1.1 This guide covers information on selection of insulation materials, systems design, application methods, protective coverings, guarantees, inspection, testing, and maintenance of thermal insulation primarily for industrial applications in a temperature range of -320 to 1200°F...
1.1 This terminology standard is a compilation of technical terms associated with testing and specifying solid electrical and electronic insulating materials. 1.2 This terminology standard shall contain all definitions that are balloted specifically through Subcommittee D09.94 and through D09 main...
1.1 This practice describes procedures for specimen preparation and mounting when testing pipe and duct insulation materials to assess flame spread and smoke development as surface burning characteristics using Test Method E84. 1.2 If the pipe or duct insulation materials to be tested...
1.1 This specification covers dry-cast hollow and solid nonloadbearing concrete masonry units machine-made from hydraulic cement, water, and suitable mineral aggregates with or without the inclusion of other materials. These units are intended for use in nonloadbearing partitions, but under certain...
This specification covers the general requirements for vacuum insulation panels (VIP). These panels have been used wherever high thermal resistance is desired in confined space applications, such as transportation, equipment, and appliances. The panel barrier consists of one or more layers...
5.1 The metal loss from corrosion is directly related to the increase in electrical resistance of the target due to the decrease in conductive cross-sectional area. 5.2 The relationship between resistance increase of metallic targets used in this test method and the amount of metal loss as reported...
1.1 This test method covers determination of the mass loss of preformed block-type and preformed pipe-covering-type thermal insulation as a result of a combination of abrasion and impact produced by a laboratory tumbling mechanism. 1.2 The values stated in inch-pound units are to be regarded...
5.1 Manufacturers of SPF insulation may need to test their products for vapor-phase emissions of volatile and semi-volatile organic compounds in order to comply with voluntary standards, purchase specifications, or other requirements. 5.2 Since SPF insulation is formed by chemical...
1.1 This method provides a qualitative measure of the corrosiveness of mineral-fiber or cellulose fiber insulation by comparison to a control. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of...
This specification covers sheet and tubular preformed flexible elastomeric cellular thermal insulation. The materials are classified into three grades according to the operating temperature range of the industrial systems that each material is used for. The non-thermoplastic, thermoset...
5.1 During operation of electrical equipment, including wires, resistors, and other conductors, it is possible for overheating to occur, under certain conditions of operation or when malfunctions occur. When this happens, a possible result is ignition of the insulation material. 5.2 This...
5.1 This test method provides a means for evaluation of the flammable performance of surface finish materials. 5.2 A specimen of the surface finish of concern is mounted on the support material contemplated for use and subjected to a controlled significant radiant-flux exposure. 5.3 All specimens...
5.1 On systems operating at sub-ambient temperature, humid ambient conditions cause a vapor driving force toward the insulation. If not retarded, the driven moisture vapor is detrimental to the insulation's thermal resistance. A vapor retarder must resist degradation in order maintain its...
4.1 Insulations that are used as a part of the thermal insulation system in contact with austenitic stainless steels have the potential to become contaminated with water soluble corrosive ions which, in turn, if permitted to reach the stainless steel surface, are possible to...
1.1 These test methods cover procedures for testing pressure-sensitive adhesive-coated tapes to be used as electrical insulation. These tapes are classified as follows: 1.1.1 Class 1-Non-elastomeric backings made from materials such as: Paper, flat or creped, Fabric, uncoated or coated,...
This specification covers mineral fiber pipe insulation that are formed into hollow cylinders for standard pipe and tubing sizes. The pipe insulation may be molded or precision v-grooved with one or more walls split longitudinally and used up to a specified temperature. The materials...
This specification covers the composition, dimensions, and physical properties of flexible unfaced foam sheet, used to insulate interior surfaces of HVAC ducts, plenums and equipment used for the distribution of conditioned air. The flexible polymeric insulations of this specification are...
This specification covers the classification and performance of flexible aerogel thermal insulation. It indicates the mechanical, chemical, and property requirements of the flexible aerogel insulation, such as its thickness, density, and flexibility. It also lists the performance...
This specification covers PB Exterior Insulation and Finish Systems (EIFS) defined as an exterior, non-bearing wall covering providing a weather-resistant exterior wall envelope on walls required to be combustible or noncombustible, fireresistance-rated
Narrow Your Results