1.1 These test methods cover transverse load testing to determine the structural properties of wall segments. 1.2 These test methods serve to evaluate the performance of wall panels subject to transverse bending loads applied perpendicular to the plane of the wall. The tests are conducted on...
1.1 These test methods cover standardized procedures for evaluating the cross-grain compression strength and stiffness of wood and wood-based products. 1.2 Two types of test methods are provided: fundamental and application methods. 1.2.1 Fundamental Test Methods-These test methods characterize the...
1.1 This specification covers coated steel sheet used in the manufacture of cold-formed framing members, such as, but not limited to, studs, joists, purlins, girts, and track. 1.2 The steel sheet used for cold-formed framing members includes metallic-coated, painted metallic-coated, or...
5.1 The impact sound rating for a floor assembly is determined both by the basic floor assembly and the floor covering on the upper surface. The same floor covering in combination with different basic floor assemblies will not always give the same impact insulation class (IIC) and high-frequency...
4.1 Test Methods E119, E1529, and other standard fire resistance test methods specify that throughout the fire-resistance test, a constant superimposed load shall be applied to a load-bearing test specimen to simulate a maximum allowable load condition. This superimposed load shall be the maximum...
5.1 This fire-test-response standard is designed to provide a basis for estimating one aspect of the fire exposure behavior to exposed insulation installed on the floors of building attics. The test environment is intended to simulate conditions that have been observed and defined in full-scale...
This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for installation in attics or enclosed spaces in housing and other buildings by pneumatic or pouring method. While the products are used in various...
3.1 Need for Lumber Grading: 3.1.1 Individual pieces of lumber, as they come from the saw, represent a wide range in quality and appearance with respect to freedom from knots, cross grain, shakes, and other characteristics. Such random pieces likewise represent a wide range in strength, utility,...
1.1 This guide covers the evaluation of hygrothermal impacts to existing roof enclosures resulting from roof enclosure alterations or changes to the interior environment. Examples of alterations that may affect the hygrothermal performance include but may not be limited to: installation of or...
This specification gives procedures for establishing, monitoring, and reevaluating structural capacities of prefabricated wood I-joists. Capacities considered are shear, moment, and stiffness. Procedures for establishing common details are given and certain design considerations specific to...
1.1 This specification provides procedures for testing and establishing the structural capacities of proprietary rim board products and assemblies for use in light-frame wood construction using I-joist or structural composite lumber joist framing. This specification does not apply to...
This specification covers the composition and physical requirements of chemically treated, recycled cellulosic fiber loose-fill type thermal insulation for installation in attics or enclosed spaces in housing and other buildings by pneumatic or pouring method. While the products are used in various...
1.1 These test methods are suitable for determining the flexural properties for any solid or hollow manufactured plastic lumber product of square, rectangular, round, or other geometric cross section that shows viscoelastic behavior. The test specimens are whole "as manufactured" pieces without any...
5.1 This fire-test-response standard is designed to provide a basis for estimating one aspect of the fire exposure behavior to exposed insulation installed on the floors of building attics. The test environment is intended to simulate conditions that have been observed and defined in full-scale...
1.1 This practice presents a laboratory procedure to determine the thermal resistance of attic insulation systems under simulated steady-state winter conditions. The practice applies only to attic insulation systems that face an open attic air space. 1.2 The thermal resistance of the insulation is...
1.1 This specification covers coated steel sheet used in the manufacture of cold-formed framing members, such as, but not limited to, studs, joists, purlins, girts, and track. 1.2 The steel sheet used for cold-formed framing members includes metallic-coated, painted metallic-coated, or...
1.1 This specification covers coated steel sheet used in the manufacture of cold-formed framing members, such as, but not limited to, studs, joists, purlins, girts, and track. 1.2 The steel sheet used for cold-formed framing members includes metallic-coated, painted metallic-coated, or...
1.1 This specification covers a type of plastic lumber product, defined as polyethylene-based structural-grade plastic lumber (SGPL), for use as main framing members, including joists, stringers, beams, columns; and secondary framing members, including planking, posts and bracing; in outdoor...
1.1 These test methods cover the non-destructive determination of the following dynamic properties of wood and wood-based materials from measuring the fundamental frequency of vibration: 1.1.1 Flexural (see Refs (1-3))2 stiffness and apparent modulus of elasticity (Etv) properties using simply or...
1.1 This test method covers the following procedures for determining the structural properties of segments of floor and roof constructions: Section Test Specimens 5 Loading 6 Deformation Measurements 7 Report 8 Precision and Bias 9 ?Testing Floors Transverse Load 10 Concentrated Load 11 ?Testing...