4.1 UV-A lamps are used in fluorescent penetrant and magnetic particle examination processes to excite fluorophores (dyes or pigments) to maximize the contrast and detection of discontinuities. The fluorescent dyes/pigments absorb energy from the UV-A radiation and re-emit visible light when...
4.1 UV-A lamps are used in fluorescent penetrant and magnetic particle examination processes to excite fluorophores (dyes or pigments) to maximize the contrast and detection of discontinuities. The fluorescent dyes/pigments absorb energy from the UV-A radiation and re-emit visible light when...
1.1 This practice covers specific procedures and test conditions for performing ultraviolet conditioning exposures on photovoltaic modules or mini-modules using fluorescent ultraviolet lamps in accordance with Practices G151 and G154. This practice covers test conditions that meet the...
1.1 This practice covers specific procedures and test conditions that are applicable for a fluorescent UV lamp and water apparatus exposure of plastics conducted in accordance with Practices G151 and G154. This practice also covers the preparation of test specimens, the test conditions best...
1.1 This specification covers commercial zinc alloys in ingot form for remelting for the manufacture of castings from the alloys as specified and designated as shown in Table 1. 1.2 Slush casting alloys are used primarily for the manufacture of hollow castings such as lighting fixtures, lamp...
4.1 This test method describes the procedure to evaluate or compare, or both, the durability of sealants when subjected to accelerated weathering and cyclic movement in a joint. 4.2 Sealant installation procedures, design considerations and movement during cure affect the aging processes and are...
5.1 The methods described represent the preferable means for calibration of field radiometers employing standard reference radiometers. Other methods involve the employment of an optical bench and essentially a point source of artificial light. While these methods are useful for cosine and azimuth...
1.1 This practice is limited to the basic principles and procedures for operating a xenon arc lamp and water apparatus; on its own, it does not deliver a specific result. 1.2 It is intended to be used in conjunction with a practice or method that defines specific exposure conditions for an...
This standard test method covers the determination of silicon in engine coolant concentrates by atomic absorption spectroscopy. Apparatus and reagents used for this test method include atomic absorption spectrometer, hollow-cathode lamp, reagent grade chemicals, standard silicon solution,...
1.1 This standard describes procedures for the determination of the relative lightfastness and weatherability of printed matter under the following conditions, which involve exposure to natural daylight or accelerated procedures in the laboratory: 1.1.1 Method 1-Daylight behind window glass, 1.1.2...
5.1 The most general method for obtaining CIE tristimulus values or, through their transformation, other coordinates for describing the colors of fluorescent objects is by the use of spectrometric data obtained under defined and controlled conditions of illumination and viewing. This practice...
Note 1: This description of the features of a Fuel-Burning Portable Device which is within the scope of this standard, together with the exceptions listed, are intended to identify device configurations that have been shown a risk of flame jetting. See X1.2. 1.1 These requirements apply to devices...
1.1 This practice covers the basic principles and operating procedures for using fluorescent light to determine color stability of plastics when materials are exposed in typical office environments where fluorescent overhead lighting and window-filtered daylight are used for illumination and where...
1.1 This practice describes a procedure for detecting subsurface flaws in composite panels and repair patches using flash thermography (FT), in which an infrared (IR) camera is used to detect anomalous cooling behavior of a sample surface after it has been heated with a spatially uniform light...
This specification covers three types of flashlights. The three types of flashlights are classified as follows: Type I; Type II; and Type III. All materials used in the construction of these flashlights shall be of a quality suitable for the purpose intended and shall conform to the requirements of...
This test method details the standard and precise procedures for the determination of lead and cadmium extracted by acetic acid from glazed ceramic surfaces. The apparatus needed for this procedure include an atomic absorption spectrometer, lead and cadmium lamps, and glassware of chemical...
This specification covers two grades of kerosine suitable for use in critical kerosine burner applications: no. 1-K - a special low-sulfur grade kerosine suitable for use in nonflue-connected kerosine burner appliances and for use in wick-fed illuminating lamps, and no. 2-K - a regular grade...
1.1 This practice specifies the operating procedures for a controlled irradiance xenon arc light and water apparatus. The procedure uses one or more lamp(s) and optical filter(s) to produce irradiance similar to sunlight in the UV and visible range. It also simulates the water absorption and...
4.1 UV-A lamps are used in fluorescent penetrant and magnetic particle examination processes to excite fluorophores (dyes or pigments) to maximize the contrast and detection of discontinuities. The fluorescent dyes/pigments absorb energy from the UV-A radiation and re-emit visible light when...
1.1 This specification covers tungsten-rhenium alloy wire suitable for use in electron devices and lamps. The material is known as UNS R07031. 1.2 The term wire as used in this specification applies to all material 0.020 in. (0.51 mm) or less in diameter that is spooled or coiled. 1.3 The...
Narrow Your Results