5.1 An articulating concrete block system is comprised of a matrix of individual concrete blocks placed together to form an erosion-resistant system with specific hydraulic performance characteristics. These systems in practice are commonly referred to as ACB revetment systems. The system includes...
1.1 This practice covers criteria to be used in defining strategies for sampling nonvolatile and semi-volatile organic chemicals on surfaces for workplace health and safety monitoring. Guidance is also given for the use of direct reading techniques, such as colorimetric measurement. 1.2 Relevant...
1.1 This test method covers collection and comparison of logs of thermalized-neutron counts and back-scattered gamma counts along horizontal or vertical air-filled access tubes. 1.2 Access tubes are installed either by drilling access holes or digging a trench into the media being measured....
5.1 Autoclave tests are commonly used to evaluate the corrosion performance of metallic and non-metallic materials under simulated HP and HTHP service conditions. Examples of service environments in which HP and HTHP corrosion tests have been used include chemical processing, petroleum production...
5.1 This practice is intended for the application of online, full-flow, or bypass, or kidney loop sampling of wear debris via inductive sensors for gearbox and drivetrain applications. 5.2 Periodic sampling and analysis of lubricants have long been used as a means to determine overall machinery...
1.1 These test methods cover procedures for determining the magnitude and rate of consolidation of soil when it is restrained laterally and drained axially while subjected to incrementally applied controlled-stress loading. Two alternative methods are provided as follows: 1.1.1 Test Method A-This...
1.1 This test method is designed to determine the properties of the structure for substrates and components used in horticulture as a growth media. The total porosity, container capacity, and air space are three properties that are determined on a percent volume basis using this method....
1.1 This guidance discusses several aspects that are critical for assessing, evaluating, and interpreting per- and polyfluoroalkyl substances (PFAS) data received from analytical laboratories: project planning, data quality assessment, data validation, and ultimately, data usability and evaluation....
1.1 This guide provides direction on the measurement of the emissions of volatile organic compounds (VOCs) from indoor materials and products using small-scale environmental test chambers. 1.2 This guide pertains to chambers that fully enclose a material specimen to be tested and does not address...
4.1 This guide is intended for use primarily by responsible parties, corrective action professionals, regulators, and others who desire to secure regulatory closure or an NFA certification from the applicable regulatory oversight agency at petroleum UST sites requiring corrective actions. While the...
5.1 Background for CPD Analyses for in vitro Vertebrate Tissue Cell Proliferation Studies-Since Leonard Hayflick's early reports on in vitro tissue cell culture studies in the 1960s, CPD data derived from serial cell culture have been used in in vitro tissue cell research as a basis for evaluating...
Heat and Mass Transfer in Drying of Porous Media offers a comprehensive review of heat and mass transfer phenomena and mechanisms in drying of porous materials. It covers pore-scale and macro-scale models, includes various drying technologies, and discusses the drying dynamics...
3.1 This test method describes a destructive test procedure for measuring the degree of seal of the porosity in anodic oxide coatings. Low coating mass loss is an indication of good seal quality and of the ability of the coating to resist staining and "blooming" in many types of service. 3.2...
1.1 This guide describes methods for determining Per- and Polyfluoroalkyl Substances (PFAS) concentrations in indoor air. 1.2 This guide is focused on PFAS measurement technologies applicable to indoor air (including in vehicles and indoor workplaces) and other relevant air volumes such as, air in...
1.1 This test method covers collection and comparison of logs of thermalized-neutron counts and back-scattered gamma counts along horizontal or vertical air-filled access tubes. 1.2 For limitations, see Section 6, "Interferences." 1.3 The in situ water content in mass per unit volume and the...
1.1 This test method provides for sampling a large volume of atmosphere, 1600?m3 to 2400?m3 (55 000?ft3 to 85 000?ft3), by means of a high flow-rate vacuum pump at a rate of 1.13?m3/min to 1.70?m3/min (40?ft3/min to 60?ft3/min) (1-4).2 1.2 This flow rate allows suspended particles having diameters...
1.1 The purpose of this test method is to provide specifications for the hydraulic testing of full-scale articulating concrete block (ACB) revetment systems under controlled laboratory conditions for purposes of identifying stability performance in steep slope, high-velocity flows. The testing...
1.1 This test method is intended to determine whether anodic oxide coatings on aluminum and its alloys, that have undergone a sealing treatment and contact with an acid solution, are stainproof or nonadsorptive with respect to dyes. 1.2 Coatings that have been properly sealed should be proof...
4.1 Emissions of VOCs are typically controlled by internal mass-transfer limitations (for example, diffusion through the material), while emissions of SVOCs are typically controlled by external mass-transfer limitations (migration through the air immediately above the material). The...
Narrow Your Results