This specification covers mortars for use in the construction of non-reinforced and reinforced unit masonry structures. Four types of mortar are covered in each of two alternative specifications: (1) proportion specifications and (2) property specifications. The property specification...
This specification covers aggregate for use in masonry mortar. Aggregate for use in masonry mortar shall consist of natural sand or manufactured sand. Manufactured sand is the product obtained by crushing stone, gravel, or air-cooled iron blast-furnace slag specially processed to...
1.1 This specification covers masonry mortars whose materials and design requirements are governed by Specification C270 but are preblended dry in a factory instead of produced from individual raw materials delivered to the job-site. 1.2 The field-sampling, testing, directly comparable test...
1.1 These test methods cover procedures for mixing and testing alkali-activated cementitious material (AACM). 1.2 These test methods and procedures appear in the following order: Sections Mechanical Mixing of Pastes and Mortars of Plastic Consistency 4 - 10 Time of Setting of Pastes by Vicat...
1.1 This specification covers mortar for the repair of masonry that was constructed with methods and materials that pre-date the origination of current standards of construction that are compatible with it. The mortar may be used for non-structural purposes such as repointing of the...
1.1 These test methods cover procedures for the sampling and testing of mortars for composition and for their plastic and hardened properties, either before or during their actual use in construction. Note 1: Guide C1586 provides guidance on evaluating mortar and clarifies the purpose...
1.1 This standard provides guidance regarding the proper use of Specification C270 and Test Method C780 for evaluating masonry mortar produced in the laboratory and at the construction site. 1.2 This international standard was developed in accordance with internationally recognized...
5.1 This test method is intended for use in comparing the bond strengths (under the given conditions) of masonry mortars. 5.2 This test method could be used, for example, to check one aspect of the quality of mortar products after production, or to indicate the bond potential of a...
5.1 This test method provides a means of determining the compressive strength of hydraulic cement and other mortars and results may be used to determine compliance with specifications. Further, this test method is referenced by numerous other specifications and test methods. Caution must be...
This specification covers mortars for use in the construction of non-reinforced and reinforced unit masonry structures. Four types of mortar are covered in each of two alternative specifications: (1) proportion specifications and (2) property specifications. The property specification...
1.1 This practice describes the apparatus and procedure for measuring relative differences in hydration kinetics of hydraulic cementitious mixtures, either in paste or mortar (see Note 1), including those containing admixtures, various supplementary cementitious materials (SCM), and other...
5.1 This test method provides a means for determining the ability of mortars and plasters to retain water when applied to specific substrates based on the intended use of the tested mortar. 5.2 The results obtained using this test method may be used to compare the relative ability of...
4.1 These test methods are used to develop data for comparison with the requirements of Specification C618 or Specification C1697. These test methods are based on standardized testing in the laboratory and are not intended to simulate job conditions. 4.1.1 Strength Activity Index-The test for...
This specification covers standard sand for use in the testing of hydraulic cements. Sand shall meet the requirements with respect to grading, source of sand, and absence of undesirable air entraining characteristics. Sieve analysis shall be performed by sieving the sand by hand or mechanically as...
4.1 The test methods in this standard are used to evaluate freshly mixed properties such as the initial flow, flow retention, and healing time as well as hardened properties such as compressive strength, setting time, and flexural strength, of self-leveling mortars. 4.2 Tests are conducted...
5.1 When the test is performed on the repair or overlay material, the result is the bond strength to the concrete panel or the tensile strength of either the overlay or concrete panel, whichever is weaker. 5.2 The measured strength is controlled by the failure mechanism requiring the least stress....
1.1 This specification covers machine-made fiberglass pipe intended for use in gravity-flow systems for conveying sanitary sewage, storm water, and some industrial wastes. Both glass-fiber-reinforc
1.1 This test method, which is applicable only to portland cements and portland-limestone cements, covers the determination of the expansion of mortar bars made from a mixture of portland cement or portland-limestone cement and gypsum in such proportions that the mixture has a sulfur...
1.1 This practice is intended to provide accepted installation procedures for thin brick units in adhered veneer systems in residential and commercial construction. This information is meant to complement the specific installation instructions provided by manufacturers of clay and shale thin brick...
1.1 This guide provides information regarding masonry elements constructed at locations other than in-place. Prefabrication may occur on the jobsite or offsite and transported to the jobsite. This guide covers lintels, arches, sloped sills, spandrels, soffits, wall panels, and other masonry...
Narrow Your Results