loading
SJI OWS - Open Web Steel Joists
January 1, 2010 - SJI
A description is not available for this item.
SJI TD 8 - Welding of Open-Web Steel Joists and Joist Girders
October 1, 2008 - SJI
A description is not available for this item.
SJI SESJ - Safe Erection of Open Web Steel Joists and Joist Girders
January 1, 2001 - SJI
A description is not available for this item.
SJI OWSJ - 85 Years of Open Web Steel Joist Construction
SJI
A description is not available for this item.
SJI TD 12 - Evaluation and Modification of Open Web Steel Joists and Joist Girders
February 1, 2007 - SJI
A description is not available for this item.
UFGS-05 21 00 - STEEL JOIST FRAMING
May 1, 2015 - NAVY

NOTE: This guide specification covers the requirements for steel joist framing and accessories and includes the following components: Open Web Steel Joists (K-Series and KCS), Longspan Steel Joists (LH-Series), Deep Longspan Steel...

ICBO MANUAL STEEL - ASD MANUAL OF STEEL CONSTRUCTION
ICBO
A description is not available for this item.
SSPC PS 14.01 - Steel Joist Shop Painting System
November 1, 1982 - SSPC

This specification covers a one-coat shop joist primer that will provide temporary protection to the steel joists during delivery and erection. This system is intended as a one-coat shop paint for open web and long span steel joists that may be...

SSPC PAINT 15 - Steel Joist Shop Primer/Metal Building Primer
May 1, 1999 - SSPC

This specification covers a one coat shop-applied primer for open web and long span steel joist and joist girders and for cold formed steel framing, and primary and secondary structural framing for metal buildings. This coating is intended to provide...

Joist hangers
October 1, 1996 - BRE

This guide shows how to use joist hangers in new construction work. It stresses the importance of correct specification and installation to ensure good performance. 8 pages. Replaces Defect Action Sheets 57 and 58. Revised 1996.

APA A750 - Builder Tips: I-Joist Blocking
April 1, 2009 - APA

Explains why I-joists benefit from being installed with blocking, blocking material composition, and installation details

ISO 19323 - Timber structures - Joist hangers - Test methods
September 1, 2018 - ISO

This document provides standard test methods for determining the vertical load, axial load and torsional moment capacity as well as deflection characteristics of preformed three-dimensional joist hangers that are used primarily for securing one timber member to another (the header can be...

JIS A 5550 - Adhesives for floor joist
March 20, 2003 - JSA
A description is not available for this item.
SJI INDEX - STEEL JOIST INSTITUTE INDEX
SJI
A description is not available for this item.
APA TT-094 - Technical Topics: Rim Board and I-Joist Nail Spacing Recommendations
April 1, 2010 - APA

Complete Title: Technical Topics: Nail Spacing Recommendations for APA EWS Rim Boards® and I-Joists

APA E715 CANADA - I-Joist Construction Details - Canadian Limit States Design
March 1, 2008 - APA

Installation guide includes recommended construction details for I-joists in floor and roof applications. Also includes details for cantilevers and web holes

NFGS 05210 - STEEL JOISTS (AND JOIST GIRDERS)
NAVY
A description is not available for this item.
ASTM D8391-22 - Standard Specification for Demonstrating Equivalent Fire Performance for Wood-Based Floor Framing Members to Unprotected 2 by 10 Dimension Lumber or Equal-Sized Structural Composite Lumber
January 1, 2022 - ASTM International

1.1 This specification provides the test methodology and procedures to demonstrate that the fire performance of wood-based floor framing members is equivalent to unprotected 2 by 10 dimension lumber or equal-sized structural composite lumber (SCL) floor joists used in interior floor...

ASTM D8391-22e1 - Standard Specification for Demonstrating Equivalent Fire Performance for Wood-Based Floor Framing Members to Unprotected 2 by 10 Dimension Lumber or Equal-Sized Structural Composite Lumber
January 1, 2022 - ASTM International

1.1 This specification provides the test methodology and procedures to demonstrate that the fire performance of wood-based floor framing members is equivalent to unprotected 2 by 10 dimension lumber or equal-sized structural composite lumber (SCL) floor joists used in interior floor...

BS 6178-1 - Joist Hangers Part 1: Joist Hangers for Building into Masonry Walls of Domestic Dwellings
September 30, 1990 - BSI

Requirement for materials, construction, protective coatings, marking, manufacturers' installation instructions and tests for steel joist hangers providing vertical support to timber floor joists. Does not cover hangers designed to transmit horizontal as well as vertical faces...

Advertisement