1.1 This test method is designed to determine the effect of exposure to high temperatures and humidities on the flexure properties of fire-retardant treated softwood plywood. In this test method, plywood is exposed to a temperature of 77?°C (170?°F). 1.2 The purpose of the test method...
1.1 These test methods cover the determination of the tensile properties of wood structural panels. 1.2 Wood structural panels in use include plywood, oriented strand board and composites of veneer, and other wood-based layers. 1.3 Test Method A, Tensile Test for Small Specimens: 1.3.1 This...
1.1 This test method covers the determination of the quantity of water absorbed in a specified time through the surface of an overlaid wood-based panel. The test method measures the rate of water gain within a controlled surface area of the overlaid panel surface when exposed to standing water. The...
1.1 This specification covers polymer modified bituminous sheet materials intended for use as underlayment on roof eaves, or valleys, or both, to prevent leakage of shingle, tile, or metal roofs from water back-up due to ice dams. 1.2 These underlayment sheets have a sticky adhesive layer which is...
5.1 The impact sound rating for a floor assembly is determined both by the basic floor assembly and the floor covering on the upper surface. The same floor covering in combination with different basic floor assemblies will not always give the same impact insulation class (IIC) and high-frequency...
4.1 Tests and criteria as outlined determine the overall usability and stability of chairs in an environment simulating the conditions of use. 4.2 Tests simulate two types of surfaces: 4.2.1 Smooth surfaces such as linoleum, wet pool decks, etc. The glass testing base (see Fig. 2) is used to...
This specification describes the required properties and test methods for high-solids content, cold liquid-applied elastomeric membrane with integral wearing surface for waterproofing building decks not subject to hydrostatic pressure. This specification does not include specific requirements for...
1.1 These test methods determine the flexural properties of strips cut from structural panels or panels up to 4?ft by 8 ft in size. Structural panels in use include plywood, waferboard, oriented strand board, and composites of veneer and of wood-based layers. Four methods of tests are...
1.1 This specification is applicable to the use of plastic lumber materials and of wood-plastic composite materials, and no other plastic composite materials, used as exterior wall coverings, as part of an exterior wall assembly. 1.2 This specification is not applicable to the use of plastic lumber...
4.1 The purpose of this standard is to provide common tree names and botanical names for commercial species and species groups but is not intended to be all inclusive of commercial practice. The decision about which commercial species are included in this practice is made by the D07 committee on...
This specification covers casein and other protein-based adhesives in the form of dry powder or granular product for use in adhering wood to wood. This specification provides testing procedures and specifies requirements to differentiate the physical, adhesive, and durability properties of...
3.1 These methods determine the compressive strength of structural panels in response to stresses acting in the plane of the panel. 3.2 Method A-This method is applicable to structural panels of uniform properties within a panel. It is useful for evaluating plywood of clear, straight-grained...
1.1 This test method is designed as a laboratory screening test. It is intended to establish an understanding of the respective contributions of the many wood material, fire-retardant, resin and processing variables, and their interactions, upon the mechanical properties of fire-retarded mat-formed...
This specification describes the required properties and test methods for high-solids content, cold liquid-applied elastomeric membrane with integral wearing surface for waterproofing building decks not subject to hydrostatic pressure. This specification does not include specific requirements for...
3.1 Planar shear (rolling shear) characteristics of structural panels determined by these test methods are essential for the rigorous design of various glued wood-panel structural components, such as box beams, folded plate roofs, and stressed skin panels. Planar shear also may govern the design at...
1.1 This practice covers the determination of strength values for clear wood of different species in the unseasoned condition, unadjusted for end use, applicable to the establishment of design values for different solid wood products such as lumber, laminated wood, plywood, and round timbers...
1.1 This practice covers the determination of strength values for clear wood of different species in the unseasoned condition, unadjusted for end use, applicable to the establishment of design values for different solid wood products such as lumber, laminated wood, plywood, and round timbers...
4.1 The purpose of this standard is to provide common tree names and botanical names for commercial species and species groups but is not intended to be all inclusive of commercial practice. The decision about which commercial species are included in this practice is made by the D07 committee on...
4.1 The thermal resistance of a ceiling system is used to characterize its steady-state thermal performance. 4.2 The thermal resistance of insulation is related to the density and thickness of the insulation. Test data on thermal resistance are obtained at a thickness and density representative of...
1.1 This test method shall be used to measure the relative corner impact resistance and other damage that may occur during the rough handling of wood-base panels or composite materials. This test method is suitable for all wood-base panels such as plywood, oriented strand board, hardboard,...