loading
AS6171/8 - Techniques for Suspect/Counterfeit EEE Parts Detection by Raman Spectroscopy Test Methods
June 28, 2022 - SAE International

To define capabilities and limitations of Raman spectroscopy as it pertains to counterfeit detection of EEE parts and suggest possible applications to these ends. Additionally, this document outlines requirements associated with the application of Raman spectroscopy...

Infrared and Raman Spectroscopy of Biological Materials
September 25, 2000 - CRC

Infrared and Raman Spectroscopy of Biological Materials facilitates a comprehensive and through understanding of the latest developments in vibrational spectroscopy. It contains explains key breakthroughs in the methodologies and techniques for infrared, near-infrared, and...

ASTM D7940-21 - Standard Practice for Analysis of Liquefied Natural Gas (LNG) by Fiber-Coupled Raman Spectroscopy
November 1, 2021 - ASTM International

1.1 This practice is for both on-line and laboratory instrument-based determination of composition for liquefied natural gas (LNG) using Raman spectroscopy. Although the procedures in this practice refer specifically to liquids, the basic methodology can also be applied to other light...

ISO 23978 - Natural gas — Upstream area — Determination of composition by Laser Raman spectroscopy
September 1, 2020 - ISO

This document describes a laser Raman spectroscopy method for the quantitative determination of chemical composition of natural gas in upstream area.

Ultrafast Infrared And Raman Spectroscopy
March 16, 2001 - CRC

A description of procedures for probing bond activation, H-bonded systems, molecular dynamical mechanisms, vibrational dephasing, simple liquids, and proteins and energy flow effects using ultrafast vibrational spectroscopy experiments. It discusses experimental and theoretical methods of...

Raman Spectroscopy: Applications in Breast Cancer Management
January 1, 2015 - SPIE

An icon in the world of optics, Emil Wolf laid the foundations of contemporary physical optics by documenting the concept of spatial coherence before lasers were introduced. This powerful concept has influenced many areas of optical science and engineering, several of which are discussed in this...

ASTM D7940-14 - Standard Practice for Analysis of Liquefied Natural Gas (LNG) by Fiber-Coupled Raman Spectroscopy
June 1, 2014 - ASTM International

1.1 This standard practice is for both on-line and laboratory instrument-based determination of composition for liquefied natural gas (LNG) using Raman spectroscopy. The basic methodology can also be applied to other light hydrocarbon mixtures in either liquid or gaseous states, if...

BS ISO 23978 - Natural gas - Upstream area - Determination of composition by Laser Raman spectroscopy
September 30, 2020 - BSI
A description is not available for this item.
ASTM D7940 - Standard Practice for Analysis of Liquefied Natural Gas (LNG) by Fiber-Coupled Raman Spectroscopy
June 1, 2014 - ASTM

This standard practice is for both on-line and laboratory instrument-based determination of composition for liquefied natural gas (LNG) using Raman spectroscopy. The basic methodology can also be applied to other light hydrocarbon mixtures in either liquid or gaseous states, if the...

RAMAN SPECTROSCOPY AND ITS APPLICATION IN NANOSTRUCTURES
WILEY
A description is not available for this item.
ASTM D8333-20 - Standard Practice for Preparation of Water Samples with High, Medium, or Low Suspended Solids for Identification and Quantification of Microplastic Particles and Fibers Using Raman Spectroscopy, IR Spectroscopy, or Pyrolysis-GC/MS
July 15, 2020 - ASTM International

5.1 Large volumes of water are required to be sieved for accurate quantification of microplastics. Water with high to medium content of suspended solids can lead to an excess of inorganic and organic background material which can interfere with the ability to conduct reliable analyses. The presence...

ASTM D8333 - Standard Practice for Preparation of Water Samples with High, Medium, or Low Suspended Solids for Identification and Quantification of Microplastic Particles and Fibers Using Raman Spectroscopy, IR Spectroscopy, or Pyrolysis-GC/MS
July 15, 2020 - ASTM

This practice provides for the sample preparation of collected water samples with high, medium, or low suspended solids to determine the presence, count, polymer type, and physical characteristics of microplastic particles and fibers. It has been designed for the preparation of samples collected...

ASTM E1654-94(2021) - Standard Guide for Measuring Ionizing Radiation-Induced Spectral Changes in Optical Fibers and Cables for Use in Remote Raman FiberOptic Spectroscopy
September 1, 2021 - ASTM International

1.1 This guide covers the method for measuring the real time, in situ radiation-induced alterations to the Raman spectral signal transmitted by a multimode, step index, silica optical fiber. This guide specifically addresses steady-state ionizing radiation (that is, alpha, beta, gamma,...

ASTM D8321-25 - Standard Practice for Development and Validation of Multivariate Analyses for Use in Predicting Properties of Petroleum Products, Liquid Fuels, and Lubricants based on Spectroscopic Measurements
October 1, 2025 - ASTM International

5.1 This practice can be used to establish the validity of the results obtained by an infrared (IR) spectrophotometer or Raman spectrometer at the time the calibration is developed. The ongoing validation of PPTMRs produced by analysis of unknown samples using the multivariate model is...

ASTM E3220-25 - Standard Guide for Characterization of Graphene Flakes
April 1, 2025 - ASTM International

1.1 This standard provides guidance on measurement approaches for the assessment of lateral flake size, average flake thickness, Raman intensity ratio of the D to G bands, and carbon/oxygen ratio for graphene and related products. The techniques included here are atomic force microscopy,...

ASTM E3406-25 - Standard Guide for Microspectrophotometry in Forensic Fiber Analysis
April 15, 2025 - ASTM International

5.1 The comparison of color is one of the key steps taken in a fiber comparison, as color is one of the most important discriminating characteristics of fibers. Microspectrophotometers allow for an objective measurement of the color (based upon selective light absorption) of small samples, which...

ASTM E3406-25e1 - Standard Guide for Microspectrophotometry in Forensic Fiber Analysis
April 15, 2025 - ASTM International

5.1 The comparison of color is one of the key steps taken in a fiber comparison, as color is one of the most important discriminating characteristics of fibers. Microspectrophotometers allow for an objective measurement of the color (based upon selective light absorption) of small samples, which...

ASTM E3501-25 - Standard Guide for Forensic Analysis of Geological Materials by Scanning Electron Microscopy and Energy Dispersive X-Ray Spectrometry
August 1, 2025 - ASTM International

4.1 This guide is intended to advise and assist analysts in the effective application of SEM/EDS to the analysis of geological materials. It is intended to be applicable to most modern SEM/EDS systems typically available in the forensic laboratory. The theoretical foundation of SEM/EDS is covered...

Advertisement