This European Standard specifies the conditions for carrying out a pull-out test on a reinforcing steel bar (rebar) anchored in a concrete block. The test applies to products based on hydraulic binders or synthetic resins or mixtures of these. It does not include those products...
This European Standard specifies a method for carrying out a sustained tensile load test on a reinforcing steel bar (rebar) anchored in a concrete block. The test is performed to determine the tensile creep under standard conditions, or under maximum service temperature...
The IRIS project is part of a wider project looking at re-engineering the processes of in-situ concrete frame construction funded under the Partner in Technology (PIT) scheme. Although the IRIS project is part of the wider project it is not directly dependent on the construction for the in-situ...
This European Standard specifies a method for determining the shear adhesion of steel rebar coated with a corrosion protection product or system and embedded in a standard reference concrete.
Provides guidelines on field inspection of rust on reinforcing steel (rebar). Includes a basic overview on corrosion, surface contaminants, mill scale and bond strength of rusted rebar
1.1 This guide covers the selection and use of procedures for testing coating powders and powder coatings. The test methods included are listed in Table 1. Where more than one test method is listed for the same characteristic, no attempt is made to indicate superiority of one...
1.1 This guide covers the selection and use of procedures for testing coating powders and powder coatings. The test methods included are listed in Table 1. Where more than one test method is listed for the same characteristic, no attempt is made to indicate superiority of one...
1.1 This guide covers the selection and use of procedures for testing coating powders and powder coatings. The test methods included are listed in . Where more than one test method is listed for the same characteristic, no attempt is made to indicate superiority of one method...
1.1 These test methods cover instructions for making a variety of tests for the strength of the adhesive bond developed between a steel anchor and the surface of a hole in concrete or masonry (including masonry units and mortar joints) and for assessing the effects on such bond of a...
These test methods are intended to provide information from which applicable design data and specifications are derived for a given anchorage device and for qualifying anchors or anchorage devices. These test methods shall be followed to ensure reproducibility of the test data.
1.1 These test methods cover instructions for making a variety of tests for the strength of the adhesive bond developed between a steel anchor and the surface of a hole in concrete or masonry (including masonry units and mortar joints) and for assessing the effects on such bond of a...
1.1 These test methods cover instructions for making a variety of tests for the strength of the adhesive bond developed between a steel anchor and the surface of a hole in concrete or masonry (including masonry units and mortar joints) and for assessing the effects on such bond of a...
INTRODUCTION Application of wet lay-up Fiber reinforced polymer (FRP) systems in the repair industry is well accepted. These applications include structural strengthening of structures such as parking garages, buildings, bridges, etc. which have experience some form of structural deficiency, many...
4.1 This standard guide applies to concrete that is still in place with a defined geometry and known, documented history. 4.2 It is not intended for use on concrete that has already been rubbelized where it is difficult to measure the radiation levels and not easy to remove surface contamination to...
This standard guide applies to concrete that is still in place with a defined geometry and known, documented history. It is not intended for use on concrete that has already been rubbelized where it is difficult to measure the radiation levels and not easy to remove surface contamination to reduce...
Introduction In general, reinforced concrete has proved to be successful in terms of both structural performance and durability because the concrete provides chemical and physical corrosion protection of the rebars. The alkaline pore solution passivates the steel and the concrete cover...
5.1 Concepts-This guide summarizes the equipment, field procedures, and data processing methods used to interpret geologic conditions, and to identify and provide locations of geologic anomalies and man-made objects with the GPR method. The GPR uses high-frequency EM waves (from 10 to 3000 MHz) to...
This Part of EN 1504 specifies requirements for the identification, performance (including durability) and safety of products and systems to be used for the anchoring of reinforcing steel (rebar) as used for structural strengthening to ensure the continuity of reinforced concrete structures....
5.1 This test method is designed to produce longitudinal tensile strength and elongation data. From a tension test, a variety of data are acquired that are needed for design purposes. Test factors relevant to the measured tensile response of bars include specimen preparation,...
Bridges play important role in modern infrastructural system. This book provides an up-to-date overview of the field of bridge engineering, as well as the recent significant contributions to the process of making rational decisions in bridge design, assessment and monitoring and resources...
Narrow Your Results