QPL-24388 - Thermocouple and Resistance Temperature Detector Assemblies, General Specification for (Naval Shipboard)
February 18, 2021 - NPFC

QUALIFIED PRODUCT LIST OF PRODUCTS QUALIFIED UNDER PERFORMANCE SPECIFICATION MIL-T-24388 Thermocouple and Resistance Temperature Detector Assemblies, General Specification for (Naval Shipboard) This list has been prepared for use by or for the Government in the acquisition of...

IEC 61224 - Nuclear Reactors - Response Time in Resistance Temperature Detectors (RTD) - In Situ Measurements
May 1, 1993 - IEC

This International Standard defines the intended criteria for the choice, conception and use of equipment for the measurement of the response time of resistance temperature detectors (RTD) which are used in the safety and control systems of nuclear reactors. The object of this...

MIL-T-24388 - THERMOCOUPLE AND RESISTANCE TEMPERATURE DETECTOR ASSEMBLIES, GENERAL SPECIFICATION FOR (NAVAL SHIPBOARD)
March 30, 1990 - NPFC

This specification covers environmentally hardened resistance thermometers and thermocouple sensors that transform the surrounding thermal energy in a manner that can be electrically measured and converted to a temperature using a signal conditioner/temperature monitor. Types...

PIP PCETE001 - Temperature Measurement Guidelines
May 1, 2014 - PIP

This Practice provides engineering guidelines for the selection and application of temperature measurement instrumentation. This Practice describes the requirements for selecting thermocouples, resistance temperature detectors, thermowells, thermistors, pyrometers,...

A-A-59954 - TEMPERATURE CALIBRATOR
June 22, 2017 - NPFC

This Commercial Item Description (CID) describes a Temperature Calibrator that is portable. Its intended purpose is to calibrate for both servo-powered and meter movement (D'arsonval) type temperature indicators. The temperature calibrator will measure and provide simulated...

PIP PCITE200 - RTD/Thermocouple Installation Details
April 1, 2014 - PIP

This Practice provides installation details for RTD (Resistance Temperature Detector) and thermocouples and describes the minimum requirements for installation.

ASTM E2821-20 - Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed Cable Used in Industrial Resistance Thermometers
May 1, 2020 - ASTM International

This specification establishes the requirements for compacted, mineral-insulated, metal-sheathed (MIMS) cables used to manufacture metal-sheathed, industrial resistance thermometers known as Resistance Temperature Detectors (RTDs). It covers the material requirements,...

ASTM E2821-13 - Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed Cable Used in Industrial Resistance Thermometers
May 1, 2013 - ASTM International

This specification establishes the requirements for compacted, mineral-insulated, metal-sheathed (MIMS) cables used to manufacture metal-sheathed, industrial resistance thermometers known as Resistance Temperature Detectors (RTDs). It covers the material requirements,...

IEC 62765-2 - Nuclear powers plants - Instrumentation and control important to safety - Management of ageing of sensors and transmitters - Part 2: Temperature sensors
January 1, 2019 - IEC

This part of IEC 62765 identifies minimum requirements and applicable practices for correcting and preventing any potential impacts on nuclear power plant (NPP) safety due to the ageing of temperature sensors, such as NPP resistance temperature detectors (RTDs) and...

PIP PCSEL001 - Procurement of Instrumentation Junction Boxes
December 1, 2007 - PIP

This Practice provides the requirements for junction boxes used for instrumentation signals, thermocouples, and resistance temperature detectors (RTDs). This Practice describes the requirements for instrumentation junction boxes and is only for junction boxes installed in...

IEC 62651 - Nuclear power plants – Instrumentation important to safety – Thermocouples: characteristics and test methods
April 1, 2013 - IEC

This International Standard describes the requirements for thermocouples suitable for nuclear power plant (NPP) applications. Thermocouples are widely used in NPPs with other temperature measurement devices such as Resistance Temperature Detectors (RTDs). They are simple...

ASTM E2821 - Standard Specification for Compacted Mineral-Insulated, Metal-Sheathed Cable Used in Industrial Resistance Thermometers
May 1, 2020 - ASTM

This specification covers the requirements for compacted, mineral-insulated, metal-sheathed (MIMS) cables used to manufacture metal-sheathed, industrial resistance thermometers referred to in this document as Resistance Temperature Detectors or RTDs. The materials of...

MIL-DTL-22612 - DETECTOR, COMBINED CONTAMINATED FUEL
January 29, 2015 - NPFC

This specification establishes the requirements for two types of combined contaminated fuel detectors. This specification is not applicable to any +100 additized petroleum products.

AS412B - Carbon Monoxide Detector Instruments
February 16, 2008 - SAE International

This Aeronautical Standard covers the basic type of carbon monoxide detector instrument used to determine toxic concentrations of carbon monoxide by the measurement of heat changes through catalytic oxidation.

MIL-DTL-51490 - Detector Kit, Chemical Agent: M256A2
January 10, 2017 - NPFC

This specification covers one type of detector kit used to determine the presence or absence of contamination from nerve, blister, blood, and lewisite chemical warfare agents. The kit includes six individually packaged M256A2 sampler detectors, four packages of Low Volatility Hazard...

BS 5343 - Specification. Gas detector tubes
February 27, 1976 - BSI

Accuracy requirements for detector tubes and their associated aspirating pumps, used for evaluating atmospheric hazards other than that of oxygen deficiency. Marking of tubes and points to cover in manufacturers' instructions.

AS412A - CARBON MONOXIDE DETECTOR INSTRUMENTS
May 1, 1991 - SAE International

This Aeronautical Standard covers the basic type of carbon monoxide detector instrument used to determine toxic concentrations of carbon monoxide by the measurement of heat changes through catalytic oxidation.