This Standard covers igneous rock (granite) plates for use in high accuracy locating, layout, and inspection work. It encompasses new certification, recertification in the field, and recertification after resurfacing. In general, the standard covers any size granite surface...
1.1 The resistance to breakage of formed catalysts, catalyst carriers, or catalyst pieces is determined by dropping a quantity of sample through a 25?ft length of 1?in. internal diameter pipe onto a steel plate. 1.2 This standard does not purport to address all of the safety concerns, if...
This specification covers plate consisting of a base metal to which is bonded, integrally and continuously, on one or both sides a layer of one of the following: titanium, zirconium, tantalum, niobium, and their alloys. The material generally is intended for pressure vessel use. The cladding...
This specification covers the requirements for electrodeposited zinc nickel alloy coatings on metals. The zinc nickel coating shall be defined as Class 1. The five chromate conversion coating types shall be defined as follows: Type A shall be with colorless conversion coatings, Type B shall be with...
1.1 This guide provides information about the deposition of chromium on steel for engineering uses. This is sometimes called "functional" or "hard" chromium and is usually applied directly to the basis metal and is usually thicker than decorative deposits. 1.2 The values stated in either SI units...
1.1 This specification covers the chemical, physical, mechanical, and metallurgical requirements for wrought nickel-titanium bar, plate, coil, and hollow containing nominally 54.5 to 57.0 weight percent nickel and used for the manufacture of medical devices and surgical implants. 1.2...
This specification covers the standard for wrought austenitic stainless steel fittings for pressure piping applications. The material for fittings shall consist of forgings, bars, plates, or seamless or welded tubular products. Forging or shaping operations shall be performed by hammering,...
4.1 Defacement of paint and coating films by fungal growth (mold, mildew) is a common phenomenon, and defacement by algal growth as referenced in Test Method D5589 can also occur under certain conditions. It is generally known that differences in the environment, lighting, temperature, humidity,...
5.1 Components of implanted medical devices can release ions, which may lead to adverse biological effects if released in sufficient quantities. Therefore, it may be necessary to characterize the ion release behavior over time to verify that a medical device or device components or both will not...
1.1 This test method covers the determination of nonvolatile residue (NVR) fallout in environmentally controlled areas used for the assembly, testing, and processing of spacecraft. 1.2 The NVR of interest is that which is deposited on sampling plate surfaces at room temperature: it is...
1.1 This guide describes the basic principles of hydrogen embrittlement (HE) and factors that can lead to hydrogen internal embrittlement (IHE) of steel components from plating and chemical processing operations. 1.2 This guide is intended for both platers and users of plated steel...
1.1 This guide describes the basic principles of hydrogen embrittlement (HE) and factors that can lead to hydrogen internal embrittlement (IHE) of steel components from plating and chemical processing operations. 1.2 This guide is intended for both platers and users of plated steel...
This specification covers the standard for wrought austenitic stainless steel fittings for pressure piping applications. The material for fittings shall consist of forgings, bars, plates, or seamless or welded tubular products. Forging or shaping operations shall be performed by hammering,...
1.1 This test method describes the continuous measurement of the hemispherical heat flux to one or both surfaces of an uncooled sensor called a "Directional Flame Thermometer" (DFT). 1.2 DFTs consist of two heavily oxidized, Inconel 600 plates with mineral insulated, metal-sheathed...
5.1 Often it is necessary to dissolve the sample, particularly if it is a solid, before atomic spectroscopic measurements. It is advantageous to use a microwave oven for dissolution of such samples since it is a far more rapid way of dissolving the samples instead of using the traditional...
4.1 A number of factors such as the condition of the entry and back surfaces of the plate, the inclination of the ultrasonic beam with respect to the entry surface, and the performance characteristics of the test system may cause either a reduction of isolated indications or a...
1.1 This specification covers carbon, low-alloy, high-strength low-alloy, and alloy steel hot-rolled floor plates for flooring, stairways, transportation equipment, and general structural purposes. While it is generally provided in the as-rolled condition, floor plate also may be...
1.1 This test method covers conducting galvanic corrosion tests to characterize the behavior of two dissimilar metals in electrical contact that are to be used in the human body as medical implants or as component parts to medical implants. Examples of the types of devices that might be assessed...
5.1 These test methods are used to measure one-dimensional vertical flow of water through initially saturated coarse-grained, pervious (that is, free-draining) soils under an applied hydraulic gradient. Measurements of hydraulic conductivity of coarse-grained soils are used in various civil...
Narrow Your Results