This set contains: TIA-322 The scope of this Standard is limited to providingengineering
4.1 While end-use product performance and durability remain critical for functionality, the focus on recycling rigid PVC products or components at their end of life needs to be intensified. Participants in the value chain (for example, material scientists, product designers, procurement, and...
4.1 Management of asbestos-containing materials in buildings and facilities requires knowledge of the location, type, quantity, and condition of the material. The more complete and accurate the information available, the more appropriate and cost-effective are the control measures used to reduce...
1.1 This guide applies to unmanned aircraft (UA) with a maximum dimension (for example, wingspan, disk diameter) =?25?ft (=?7.68 m) operating at airspeeds below 100?kts and of any configuration or category. It is meant to be applied in a "lower risk" (low- and medium-risk airspace as described by...
5.1 Amine-based scavengers are commonly used to abate sour gas from hydrocarbon streams via a stoichiometric reaction with hydrogen sulfide. Some of these amines can contribute to downstream amine-chloride corrosion and fouling of crude oil fractionation towers and overhead condensers. The...
1.1 This specification covers fired ceramic shapes formed from naturally occurring clays and from compounded bodies that are used as packing in tower installations. These ceramic units are designed primarily for use in process equipment for the chemical or allied industries. 1.2 The physical...
1.1 This practice outlines a procedure for evaluating the efficacy of microbicides (algicides, bactericides, and fungicides) that will be used for controlling microbial growth in cooling water systems. The microbicides will be evaluated using simulated or real cooling tower water against (1)...
1.1 This specification covers re-refined engine oil bottoms, also known as vacuum tower asphalt extender, that may be used in formulating asphalt for pavement construction and roofing. This specification has been developed specifically for these two categories of product and is not intended...
5.1 This standard provides guidance for using cryptographic credentials to secure localized A2X-Direct communications as defined in 5.3. It is not intended to specify or infer the security requirements for any one A2X application or underlying communications link, though significant attention is...
This specification establishes the requirements for treestands, climbing sticks, and tripod/tower stands that are used for hunting, photographing, or general observation. It covers ladder treestands; non-climbing, fixed position or hang-on treestands; climbing sticks (continuous); climbing...
1.1 This specification covers the chemical and mechanical requirements of hexagon and square-head zinc-coated steel bolts and atmospheric corrosion-resistant bolts, in nominal thread diameters of 1/2 , 5/8 , 3/4 , 7/8 and 1 in. for use in the construction of transmission towers, substations,...
1.1 This standard specifies the minimum strength requirements for anchorages permanently installed or attached to training towers or other structures used for rope rescue training. It does not describe how those anchorages are constructed, installed in, or attached to the structure, nor does...
1.1 This test method covers procedures for static loading of various components of treestands, climbing sticks, and tripod/tower stands that are used for hunting, photographing, or general observation. This test method includes the corresponding factors of safety that each component should...
1.1 This test method covers procedures for a quantitative accelerated laboratory evaluation of the influence of extraction solutions containing ions leached from thermal insulation on the aqueous corrosion of carbon steel. The primary intent of the practice is for use with thermal insulation and...
5.1 This practice is provided to develop and maintain uniformity in practices for instructions for treestands, climbing sticks (continuous and sectional), tripods, and towers, particularly with regard to quality assurance and safety. 5.2 It is emphasized that the use of these practices will...
1.1 This specification covers glass in permanent railing systems, guards, and balustrades, including components such as rails and swing gates or other forms of required guardrail opening protection installed in agricultural, assembly, comme- rcial, educational, industrial, institutional,...
1.1 This guide is intended to provide building users such as private building owners, contractors, architects, homeowners, and regulatory authorities with assistance in selecting an appropriate liquid coating encapsulation product for architectural residence and child-care facility use situations...
1.1 This specification covers re-refined engine oil bottoms, also known as vacuum tower asphalt extender, that may be used in formulating asphalt for pavement construction and roofing. This specification has been developed specifically for these two categories of product and is not intended...
Table of Contents Section Title Section/Paragraph ?Scope 1 ?Referenced Documents 2 ?Terminology 3 ?Significance and Use 4 Pole and Tree Climbers ?Classification 5 ?Ordering Information 6 ?Pole and Tree Climbers 7 ?Climber Gaffs 8 ?Climber Straps 9 ?Climber Pads 10 ?Climber Footplates 11 Body Belts,...
1.1 These practices cover procedures for measuring one-, two-, or three-dimensional vector wind components and sonic temperature by means of commercially available sonic anemometer/thermomet