loading
IEEE C57.12.37 - The Electronic Reporting of Distribution Transformer Test Data
September 3, 2015 - IEEE

This standard provides a basis for electronic reporting of transformer test data on liquid-immersed distribution transformers. This standard defines how to format and report the standard test data when electronic reporting is specified. In addition, it defines an...

IEEE C57.98 - Guide for Transformer Impulse Tests
December 11, 2011 - IEEE

To aid in the interpretation and application of the impulse testing requirements of the IEEE Standard Test Codes for Transformers. Purpose This guide is written primarily for power transformers, but it is also generally applicable to distribution and instrument...

IEEE 1388 - Standard for the Electronic Reporting of Transformer Test Data
December 7, 2000 - IEEE

This standard provides a basis for electronic reporting of transformer test data on liquid immersed distribution transformers, specifically, those defined in the ANSI C57.12.2X standards series. This standard defines the standard set of test data to be reported and the...

IEEE 93 - GUIDE FOR TRANSFORMER IMPULSE TESTS
June 21, 1968 - IEEE
A description is not available for this item.
NG SCT 20.01 - Site Commissioning Tests - Current Transformers Mangnetisation Tests
April 1, 2014 - NG

PURPOSE AND SCOPE This document contains the site commissioning tests to be performed on Current Transformers in National Grid (NG) substations.'

DSF/PREN 50708-2-4 - Power transformers – Additional European requirements – Part 2-4: Medium power transformer – Special tests
DS

This document describes the special test for Medium Power Transformers ≤ 3150kVA compliant with the EN 50708 2 series: - for corrugated tank liquid immersed transformers; - for the method of measurement of losses for one winding in Highest Voltage (HV) and 2 windings in Lowest...

IEEE 389 - Recommended Practice for Testing Transformers and Inductors for Electronics Applications
March 5, 2020 - IEEE

This recommended practice presents a number of tests for use in determining the significant parameters and performance characteristics of electronics transformers and inductors. These tests are designed primarily for transformers and inductors used in all types of...

ANSI C12.9 - Test Switches and Plugs for Transformer-Rated Meters
January 1, 2014 - NEMA

This standard is intended to encompass the dimensions and functions of meter test switches used with transformer-rated watthour meters in conjunction with instrument transformers and test plugs used in conjunction with the test switch.

PIP ELSCP01 - Cathodic Protection Transformer Rectifier
September 1, 2020 - PIP

This Practice provides requirements for design, manufacturing, and testing of impressed cathodic protection system transformer-rectifiers.

DSF/PREN 50708-3-4 - Power transformers – Additional European requirements – Part 3-4: Large power transformer – Special tests for corrugated tank and radiators
DS

This document describes a special test for hermetically sealed transformers with integral filling equipped with corrugated tank or tank with expandable radiators for Large Power Transformers > 3 150 kVA.

Power Transformer Design Practices
March 19, 2021 - CRC

The book presents basic theories of transformer operation, design principles and methods used in power transformer designing work, and includes limitation criteria, effective utilization of material, and calculation examples to enhance readers' techniques of transformer design...

DIN 44766-4 - Resistance welding transformers; requirements, tests
May 1, 1981 - DIN
A description is not available for this item.
Electric Power Transformer Engineering
May 16, 2012 - CRC

Electric Power Transformer Engineering, Third Edition expounds the latest information and developments to engineers who are familiar with basic principles and applications, perhaps including a hands-on working knowledge of power transformers. Targeting all from the merely curious to...

NR RT/E/WI/27055 - Instruction for Routine Testing & Maintenance of Transformer & Switchgear Oil
December 4, 2004 - NR

This Instruction applies to uninhibited insulating oils in transformers, switchgear and similar apparatus where sampling is practicable. Low oil volume equipment which does not contain a reserve of oil for testing purposes, or equipment which is not designed for the process of routine...

MIL-T-48319 - TRANSFORMER
NPFC
A description is not available for this item.
IEEE C57.123 - Guide for Transformer Loss Measurement
November 7, 2019 - IEEE

This guide provides background information and general recommendations of instrumentation, circuitry, calibration, and measurement techniques of no-load losses (excluding auxiliary losses), excitation current, load losses of power, and distribution transformers. The test codes,...

NEMA TP 3 - Standard for the Labeling of Distribution Transformer Efficiency
January 1, 2000 - NEMA

Defines the labeling of distribution transformers tested to the efficiency levels specified in TP 1. This standard defines the labeling of distribution transformers tested to the efficiency levels specified in TP 1. The label shall be affixed to the transformer in...

IEEE C57.138 - Recommended Practice for Routine Impulse Tests for Distribution Transformers
December 7, 2016 - IEEE

This recommended practice covers routine impulse tests performed on distribution transformers, as required in IEEE Std C57.12.00™, and described in 10.4 of IEEE Std C57.12.90™-20151. Distribution transformers covered by this recommended practice are liquid-immersed, single- and...

DS/EN 60076-4 - Power transformers - Part 4: Guide to lightning impulse and switching impulse testing - Power transformers and reactors
October 24, 2002 - DS

This part of IEC 60076 gives guidance and explanatory comments on the existing procedures for lightning and switching impulse testing of power transformers to supplement the requirements of IEC 60076-3. It is also generally applicable to the testing of reactors, see IEC 60289;...

NR/L3/ELP/27240/NR/DISC4C - Instruction for Testing and Maintenance of Transformer and Switchgear Insulating Oil
June 1, 2017 - NR

Includes: Group 1: Transformers (high priority) e.g. grid transformers, including the selector tanks of on-load tap changers and isolating transformers. Group 2: Transformers (low priority) e.g. booster transformers, regulating transformers, auxiliary...

Advertisement