5.1 It is possible for insulating materials used in high-voltage equipment to be subjected to transient voltage stresses, resulting from such causes as nearby lightning strokes. This is particularly true of apparatus such as transformers and switchgear used in electrical-power...
1.1 These test methods may be used to determine the water content of soils and the dry density of soils in place using Time Domain Reflectometry. 1.2 These test methods apply to soils that have 30?% or less by weight of their particles retained on the 19.0-mm [3/4-in.] sieve. 1.3 These test methods...
This specification establishes functional operation and minimum performance requirements for simple systems that provide angle-of-attack information to a pilot, aircraft, or other systems. Functional requirements cover basic operation, stall indication, startup of electronically driven systems,...
This specification covers a high fire point natural vegetable oil ester insulating fluid for use as a dielectric and cooling medium in new and existing power and distribution electrical apparatus such as transformers and attendant equipment. The physical property requirement including color, fire...
5.1 The presence of 4-CBA and p-TOL in PTA used for the production of polyester is undesirable because they can slow down the polymerization process; and 4-CBA is also imparting coloration to the polymer due to thermal instability. 5.2 Determining the amount of 4-CBA and p-TOL remaining from the...
5.1 The presence of 4-CBA and p-TOL in PTA used for the production of polyester is undesirable because they can slow down the polymerization process; and 4-CBA is also imparting coloration to the polymer due to thermal instability. 5.2 Determining the amount of 4-CBA and p-TOL remaining from the...
1.1 This practice covers the nondestructive testing of field seams in geomembranes using the spark test. A suspect area is indicated by the generation of a spark. The test is applicable to seams made by the extrusion method, seams made by using welding tape (a strip of the same type of material as...
1.1 These reference radiographs for gray iron castings consist of one set of illustrations of centerline shrinkage with severity levels 1 to 5 using three radiation source types as follows: 1.1.1 Volume I: Medium Voltage (Nominal 250 kVp) X-ray Reference Radiographs-Set of 5 severity levels...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in steel castings that have section thicknesses up to 2 in. (50.8 mm) (see Note 2). The reference radiograph films are an adjunct to this standard and must be purchased separately...
1.1 These reference radiographs illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The reference radiograph films are an adjunct to this document and must be purchased separately from ASTM International if needed (see 2...
1.1 These digital reference images illustrate various categories, types, and severity levels of discontinuities occurring in tin bronze and related alloy castings. The digital reference images are an adjunct to this document and must be purchased separately from ASTM International if needed (see...
1.1 These test methods cover procedures for testing rigid electrical insulation normally manufactured in flat sheet or plate form. They are generally used as terminal boards, spacers, voltage barriers, and circuit boards. 1.2 Use Test Methods D619 (withdrawn) or Specification D710 for tests...
1.1 This guide covers methods of calibration and use of thermocouple reference junction probes (cold junction compensation probes) in the evaluation of electronic reference junction compensation circuits. Their use with instruments that measure only voltage is also covered. 1.2 The values...
1.1 These test methods cover procedures for testing pressure-sensitive adhesive-coated tapes to be used as electrical insulation. These tapes are classified as follows: 1.1.1 Class 1-Non-elastomeric backings made from materials such as: Paper, flat or creped, Fabric, uncoated or coated, Cellulose...
3.1 This specification provides designers and manufacturers of electric propulsion for light sport aircraft design references and criteria to use in designing and manufacturing EPUs. 3.2 Declaration of compliance is based on testing and documentation during the design, ground testing and flight...
5.1 PN Junction Diode-The steady-state photocurrent of a simple p-n junction diode is a directly measurable quantity that can be directly related to device response over a wide range of ionizing radiation. For more complex devices, the junction photocurrent may not be directly related to device...
4.1 This test method describes the procedure to evaluate or compare, or both, the durability of sealants when subjected to accelerated weathering and cyclic movement in a joint. 4.2 Sealant installation procedures, design considerations and movement during cure affect the aging processes and are...
2.1 The significance of the variables set forth in this guide was proved by various laboratories using several test systems at test currents ranging from 100 A to 35 000 A. These variables will be significant for any case where voltage and current are sufficient to produce arcing.
1.1 This specification covers the testing of insulated and insulating hand tools used for working on, or in close proximity to, energized electrical apparatus or conductors operating at maximum voltage of 1000 V ac or 1500 V dc. 1.2 The specific use of these tools is beyond the scope of this...