This comprehensive manual includes information on clear water repellent materials for both vertical and horizontal surfaces. Also included are a glossary, product comparisons, specifications, monograph and performance test criteria.
5.1 This guide applies to commonly used surface geophysical methods for those applications listed in Table 1. The rating system used in Table 1 is based upon the ability of each method to produce results under average field conditions when compared to other methods applied to the same application....
5.1 This guide applies to commonly used surface geophysical methods for those applications listed in Table 1. The rating system used in Table 1 is based upon the ability of each method to produce results under average field conditions when compared to other methods applied to the same application....
This standard describes two performance classes of potable cold-water meters of the electromagnetic and ultrasonic type, in sizes 1/2 in. (13 mm) through 20 in. (500 mm), for revenue applications, and the materials and workmanship employed in their fabrication. Type I. This type...
1.1 This test method covers the measurement of flow rate of water in open channels, streams, and closed conduits with a free water surface. 1.2 The test method covers the use of acoustic transmissions to measure the average water velocity along a line between one or more...
5.1 This Standard Test Method is intended for use in calibrating hand-held meters to accurately read from approximately 30 to 90 % ERH. Moisture content is related to the ERH or water activity of a material. 5.2 Hand-held meters provide a rapid means of sampling the moisture...
The new and updated 2007 Clear Water Repellent Manual is a source of un-biased information that can make sense of a topic that is often either oversold or misunderstood. This manual has all the makings of a great training program as well as an overall education piece and discusses the...
This European Standard specifies performance test methods for control equipment. Furthermore, this document contains requirements on accuracy, durability and reliability of control equipment. The tests described in this document are limited to electrically activated components delivered with...
This European Standard specifies performance test methods for control equipment. Furthermore, this document contains requirements on accuracy, durability and reliability of control equipment. The tests described in this document are limited to electrically activated components delivered with...
API MPMS Chapter 5.3 and parts of API MPMS Chapter 6 cover the installation requirements and performance characteristics of turbine meters in liquid hydrocarbon service. This research work provides data that should be considered for future incorporation into these standards. Phase I of this...
5.1 Concepts: 5.1.1 This guide summarizes the basic equipment, field procedures, and interpretation methods used for detecting, delineating, or mapping shallow subsurface features and relative changes in layer geometry or stratigraphy using the seismic-reflection method. Common applications of the...
5.1 Concepts-This guide summarizes the equipment, field procedures, and interpretation methods used for the determination of subsurface conditions due to density variations using the gravity method. Gravity measurements can be used to map major geologic features over hundreds of square miles and to...
Narrow Your Results