This test method tests the hydrostatic resistance of a waterproofing membrane and can be used to compare the hydrostatic resistance of waterproofing membranes. No correlation has been established between the performance in this test method and that in the field.
3.1 This test method tests the hydrostatic resistance of a waterproofing membrane and can be used to compare the hydrostatic resistance of waterproofing membranes. 3.2 No correlation has been established between the performance in this test method and that in the field.
3.1 This test method tests the hydrostatic resistance of a waterproofing membrane and can be used to compare the hydrostatic resistance of waterproofing membranes. 3.2 No correlation has been established between the performance in this test method and that in the field.
This specification covers three types of deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. Type I are cold liquid-applied chemically curing membrane materials that that require a membrane protection...
This specification covers deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI...
This specification covers three types of deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. Type I are cold liquid-applied chemically curing membrane materials that that require a membrane protection...
1.1 This specification covers deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
1.1 This specification covers deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
This specification covers three types of deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. Type I are cold liquid-applied chemically curing membrane materials that that require a membrane protection...
1.1 This test method measures the hydrostatic resistance of a waterproofing membrane under controlled laboratory conditions. This test method is not suitable for systems that rely on confinement of the seams by the backfill since backfill is not part of this test method. 1.2 The...
This test method measures the hydrostatic resistance of a waterproofing membrane under controlled laboratory conditions. This test method is not suitable for systems that rely on confinement of the seams by the backfill since backfill is not part of this test method. The values stated...
5.1 Dynamic mechanical analysis provides a measure of the rheological properties of roofing and waterproofing membrane materials. 5.2 Thermogravimetry is used to characterize the thermal stability of roofing and waterproofing membrane materials under the specific...
5.1 Dynamic mechanical analysis provides a measure of the rheological properties of roofing and waterproofing membrane materials. 5.2 Thermogravimetry is used to characterize the thermal stability of roofing and waterproofing membrane materials under the specific...
Dynamic mechanical analysis provides a measure of the rheological properties of roofing and waterproofing membrane materials. Thermogravimetry is used to characterize the thermal stability of roofing and waterproofing membrane materials under the specific temperature...
Dynamic mechanical analysis provides a measure of the rheological properties of roofing and waterproofing membrane materials. Thermogravimetry is used to characterize the thermal stability of roofing and waterproofing membrane materials under the specific temperature...
This guidebook provides a comprehensive overview dealing with below grade waterproofing. Illustrations, photographs and highlights of the importance of proper design, material selection, surface preparation and problem solving are included.
This test method measures the hydrostatic resistance of a waterproofing membrane under controlled laboratory conditions. This test method is not suitable for systems that rely on confinement of the seams by the backfill since backfill is not part of this test method. The values stated...
1.1 This test method describes a laboratory procedure for determining the average nonvolatile content for one- or two-component cold liquid-applied elastomeric waterproofing membranes. 1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are...