IEEE C57.13.1

Guide for Field Testing of Relaying Current Transformers

inactive
Buy Now
Organization: IEEE
Publication Date: 16 November 2006
Status: inactive
Page Count: 39
scope:

The scope of this guide is to describe field test methods that assure current transformers (CTs) are connected properly, are of marked ratio and polarity, and are in a condition to perform as designed both initially and after being in service for a period of time.

Annex A describes wiring integrity checks, uses of test jacks and current shorting switch, and relay test equipment.

Annex B illustrates excitation voltage measurement differences between rms responding voltmeters, commonly used under field conditions, and average responding voltmeters commonly used in laboratory tests and also discusses the effect of the source impedance.

Annex C describes the characteristics, and other pertinent information, for optical current sensor systems used with protective relaying. It provides an overview of the components used in an optical sensor system, discusses the differences from conventional CTs, and provides testing information.

Annex D is the bibliography for this guide.

Purpose

The purpose of the guide is to provide information on the current technology for field testing of instrument transformers and to more closely coordinate the information with the other industry standards, for example, National Electrical Safety Code® (NESC®).

Document History

December 6, 2017
Guide for Field Testing of Relaying Current Transformers
The scope of this guide is to describe field test methods that assure current transformers (CTs) are connected properly, are of marked ratio and polarity, and are in a condition to perform as...
November 16, 2006
Guide for Field Testing of Relaying Current Transformers
The scope of this guide is to describe field test methods that assure current transformers (CTs) are connected properly, are of marked ratio and polarity, and are in a condition to perform as...
IEEE C57.13.1
November 16, 2006
Guide for Field Testing of Relaying Current Transformers
The scope of this guide is to describe field test methods that assure current transformers (CTs) are connected properly, are of marked ratio and polarity, and are in a condition to perform as...
January 1, 1981
Guide for Field Testing of Relaying Current Transformers
Foreword  (This Foreword is not a part of ANSI/IEEE C57.13.1-1981, IEEE Guide for Field Testing of Relaying Current Transformers.) This guide was prepared by a Working Group of the Relay Input...