ASTM D7225-13(2019)e1 - Standard Guide for Blood Cleaning Efficiency of Detergents and Washer-Disinfectors
May 1, 2019 - ASTM International

4.1 Significance-Dried blood represents a significant challenge to cleaning surgical instruments. The water-soluble components of blood are easily rendered insoluble when exposed to heat, chemical solutions, or time at room temperature. The water insoluble component of blood is fibrin...

ASTM F3218-19 - Standard Practice for Documenting Environmental Conditions for Utilization with A-UGV Test Methods
September 1, 2019 - ASTM International

4.1 This section provides a description of the environmental conditions listed in Section 1 and describes the sub-conditions within each condition. Examples provided for many of the conditions and sub-conditions are provided as guidance only. Each of the conditions described should be evaluated and...

ASTM F1334 - Standard Test Method for Determining A-Weighted Sound Power Level of Vacuum Cleaners
October 1, 2018 - ASTM

This test method calculates the overall A-weighted sound power level emitted by small portable upright, canister, combination vacuum cleaners, backpack vacuum cleaners, hard-floor cleaning machines, extractors, and central vacuum cleaner motorized nozzles intended for operation in domestic...

ASTM F1334-18 - Standard Test Method for Determining A-Weighted Sound Power Level of Vacuum Cleaners
October 1, 2018 - ASTM International

1.1 This test method calculates the overall A-weighted sound power level emitted by small portable upright, canister, combination vacuum cleaners, backpack vacuum cleaners, hard-floor cleaning machines, extractors, and central vacuum cleaner motorized nozzles intended for operation in...

ASTM E1560-18 - Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers
November 1, 2018 - ASTM International

5.1 The NVR obtained by this test method is that amount which is available for release by wipers in normal use. 5.2 Evaporation of the solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room...

ASTM E1731-11(2018) - Standard Test Method for Gravimetric Determination of Nonvolatile Residue from Cleanroom Gloves
November 1, 2018 - ASTM International

5.1 The NVR obtained by this test method is that amount which is available for release by the gloves onto handled surfaces. 5.2 Evaporation of solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between...

9986495 - Adhesive/Sealant, Silicone, Room Temperature Vulcanizing, Oxime Cure for Engine Sealing
July 1, 2018 - GMNA

Note: The words must, shall or will as used in this document mean a mandatory requirement. Material Description. This silicone adhesive/sealant requires no catalyst or heat to cure. When applied wet (uncured) it reacts with moisture in the air (condensation cure) releasing an alcohol (methanol)...

IEC 60335-2-102 REDLINE - Household and similar electrical appliances – Safety – Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections
December 1, 2017 - IEC

This International Standard deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliance This standard covers the...

IEC 60335-2-102 - Household and similar electrical appliances – Safety – Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections
December 1, 2017 - IEC

This International Standard deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard covers the...

ASTM F50-12(2015) - Standard Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms Using Instruments Capable of Detecting Single Sub-Micrometre and Larger Particles
October 1, 2015 - ASTM International

5.1 The primary purpose of this practice is to describe a procedure for collecting near real-time data on airborne particle concentration and size distribution in clean areas as indicated by single particle counting techniques. Implementation of some government and industry specifications...

9986499 - Adhesion Promoter Coating for Room Temperature Vulcanized (RTV) Sealants
May 1, 2017 - GMNA

Purpose. To define the product, its qualifications for use including application methods and monitoring the applied coating in the end use application. This specification describes a ready-to-use, single source liquid that dries' to a thin coating before application of Room Temperature...

FMAPPROVAL 4882 - Class 1 Interior Wall and Ceiling Materials or Systems for Smoke Sensitive Occupancies
December 1, 2016 - FM

This standard applies to interior wall and ceiling materials or systems used in cleanrooms, pharmaceutical manufacturing and storage areas, food preparation and storage areas and similar occupancies or other occupancies which are susceptible to smoke damage. Wall and ceiling materials or systems...

ASTM F565-04(2018) - Standard Practice for Care and Handling of Orthopedic Implants and Instruments
February 1, 2018 - ASTM International

This practice covers recommended procedures for the handling of orthopedic implants and instruments. Hospital receiving personnel, central supply personnel, operating room personnel, surgeons, and occasionally other individuals will handle orthopedic implants and instruments. All personnel...

9985990 - Adhesive, Room Temperature Vulcanizing (RTV), Silicone, One-Part
May 1, 2017 - GMNA

Note: The words must, shall or will as used in this document mean a mandatory requirement. Material Description. This specification covers a one-part, room temperature vulcanizing (RTV), oxime cure silicone rubber, formed-in-place gasket (FIPG). The system must be capable of being, dispensed...

DS/EN 60335-2-102 - Household and similar electrical appliances - Safety - Part 2-102: Particular requirements for gas, oil and solid-fuel burning appliances having electrical connections
March 14, 2016 - DS

Deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The electrical safety and some other safety aspects of...

9986496 - Adhesive/Sealant, Polyacrylate, Room Temperature Vulcanizing, Alcohol Cure for Axle Sealing
March 1, 2017 - GMNA

Material Description. This Polyacrylate (ACM) adhesive/sealant requires no catalyst or heat to cure. When applied it reacts with moisture in the air releasing an alcohol by-product and fully cures to an elastomeric product, adhering to most clean surfaces without need of a primer. Adhesively...

ASTM F3218-17 - Standard Practice for Recording Environmental Effects for Utilization with A-UGV Test Methods
July 1, 2017 - ASTM International

4.1 Lighting: 4.1.1 Various lighting conditions can potentially affect A-UGV optical sensor performance by affecting sensor and in turn, A-UGV responsiveness. Lighting sources can include ambient lighting as well as light emitters associated A-UGV operation. Two setups for lighting include direct...

ASTM F2608 - Standard Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning Process
November 1, 2015 - ASTM

This test method provides a laboratory test for the measurement of particulate generated as a direct result of the vacuuming process. This test method is applicable to all residential/ commercial uprights, canisters, stickvacs, central vacuum systems, and combination cleaners. This test method...

ASTM F2608-15 - Standard Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning Process
November 1, 2015 - ASTM International

4.1 In this test method, the amount of particulate generated into the air by operating a vacuum cleaner over a specific floor covering that is contaminated with dust will be determined. Particles from the motor, floor covering, and the test dust will all be measured. The amount of dust generated in...

ASTM F2608-15e1 - Standard Test Method for Determining the Change in Room Air Particulate Counts as a Result of the Vacuum Cleaning Process
November 1, 2015 - ASTM International

4.1 In this test method, the amount of particulate generated into the air by operating a vacuum cleaner over a specific floor covering that is contaminated with dust will be determined. Particles from the motor, floor covering, and the test dust will all be measured. The amount of dust generated in...