4.1 Significance-Dried blood represents a significant challenge to cleaning surgical instruments. The water-soluble components of blood are easily rendered insoluble when exposed to heat, chemical solutions, or time at room temperature. The water insoluble component of blood is fibrin...
4.1 This section provides a description of the environmental conditions listed in Section 1 and describes the sub-conditions within each condition. Examples provided for many of the conditions and sub-conditions are provided as guidance only. Each of the conditions described should be evaluated and...
This test method calculates the overall A-weighted sound power level emitted by small portable upright, canister, combination vacuum cleaners, backpack vacuum cleaners, hard-floor cleaning machines, extractors, and central vacuum cleaner motorized nozzles intended for operation in domestic...
1.1 This test method calculates the overall A-weighted sound power level emitted by small portable upright, canister, combination vacuum cleaners, backpack vacuum cleaners, hard-floor cleaning machines, extractors, and central vacuum cleaner motorized nozzles intended for operation in...
5.1 The NVR obtained by this test method is that amount which is available for release by wipers in normal use. 5.2 Evaporation of the solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between room...
5.1 The NVR obtained by this test method is that amount which is available for release by the gloves onto handled surfaces. 5.2 Evaporation of solvent at the stated temperature is to quantify the NVR that can be expected to exist at room temperature, since the slight difference between...
Note: The words must, shall or will as used in this document mean a mandatory requirement. Material Description. This silicone adhesive/sealant requires no catalyst or heat to cure. When applied wet (uncured) it reacts with moisture in the air (condensation cure) releasing an alcohol (methanol)...
This International Standard deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliance This standard covers the...
This International Standard deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. This standard covers the...
5.1 The primary purpose of this practice is to describe a procedure for collecting near real-time data on airborne particle concentration and size distribution in clean areas as indicated by single particle counting techniques. Implementation of some government and industry specifications...
Purpose. To define the product, its qualifications for use including application methods and monitoring the applied coating in the end use application. This specification describes a ready-to-use, single source liquid that dries' to a thin coating before application of Room Temperature...
This standard applies to interior wall and ceiling materials or systems used in cleanrooms, pharmaceutical manufacturing and storage areas, food preparation and storage areas and similar occupancies or other occupancies which are susceptible to smoke damage. Wall and ceiling materials or systems...
This practice covers recommended procedures for the handling of orthopedic implants and instruments. Hospital receiving personnel, central supply personnel, operating room personnel, surgeons, and occasionally other individuals will handle orthopedic implants and instruments. All personnel...
Note: The words must, shall or will as used in this document mean a mandatory requirement. Material Description. This specification covers a one-part, room temperature vulcanizing (RTV), oxime cure silicone rubber, formed-in-place gasket (FIPG). The system must be capable of being, dispensed...
Deals with the safety of gas, oil and solid-fuel burning appliances having electrical connections, for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances. The electrical safety and some other safety aspects of...
Material Description. This Polyacrylate (ACM) adhesive/sealant requires no catalyst or heat to cure. When applied it reacts with moisture in the air releasing an alcohol by-product and fully cures to an elastomeric product, adhering to most clean surfaces without need of a primer. Adhesively...
4.1 Lighting: 4.1.1 Various lighting conditions can potentially affect A-UGV optical sensor performance by affecting sensor and in turn, A-UGV responsiveness. Lighting sources can include ambient lighting as well as light emitters associated A-UGV operation. Two setups for lighting include direct...
This test method provides a laboratory test for the measurement of particulate generated as a direct result of the vacuuming process. This test method is applicable to all residential/ commercial uprights, canisters, stickvacs, central vacuum systems, and combination cleaners. This test method...
4.1 In this test method, the amount of particulate generated into the air by operating a vacuum cleaner over a specific floor covering that is contaminated with dust will be determined. Particles from the motor, floor covering, and the test dust will all be measured. The amount of dust generated in...
4.1 In this test method, the amount of particulate generated into the air by operating a vacuum cleaner over a specific floor covering that is contaminated with dust will be determined. Particles from the motor, floor covering, and the test dust will all be measured. The amount of dust generated in...