loading
GMKOREA EDS-T-4568 - Test Procedure of Measure Pad to Frame Noise
September 1, 2011 - GMKOREA

Seats with separate pads and frames PURPOSE This procedure verifies generation of noise from the friction between the pad and the frame during movement of passengers.

DS/EN 12412-2 - Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames
November 20, 2003 - DS

This European Standard specifies a method, based on EN ISO 8990 and EN ISO 12567-1, to measure the thermal transmittance of frame and sash components of windows and doors, including mullions and transoms.

BS ISO 11928-2 - Micrographics - Quality Control of Graphic COM Recorders - Part 2: Quality Criteria and Control
May 15, 2000 - BSI

Methods for measuring frame size, resolution, radial recording and curved lines, with advice on checking line density and character display and rotation

BS 7353 - Methods of Measuring Quality of Output of Graphic COM Recorders
February 28, 1991 - BSI

Methods for measuring frame size, resolution, radial recording and curved lines, with advice on checking line density and character display and rotation.

AGMA 01FTM5 - Traceability of Gears - New Ideas, Recent Developments
October 1, 2001 - AGMA

Some national standard tolerances for cylindrical gears lie in, and even below, the range of instrument measurement uncertainties. This paper presents a concept based on three fundamental goals: reduction of measurement uncertainty, construction of workpiece-like standards, and shortening of the...

ITU-T O.163 - EQUIPMENT TO PERFORM IN-SERVICE MONITORING ON 1544 kbit/s SIGNALS
November 1, 1988 - ITU-T

General This specification describes frame alignment signal monitoring equipment for 1544 kbit/s frame structures that are in accordance with Recommendation G.704 [1]. This equipment is intended to monitor 12-frame multiframe (superframe format - SF) or 24-frame...

UL 10C - Positive Pressure Fire Tests of Door Assemblies
June 9, 2016 - ULSE

00010c-000000-000000 1 Scope 1.1 These methods of fire tests are applicable to swinging door assemblies, including door frames with lights and panels, of various materials and types of construction for use in wall openings to retard the passage of fire. The method does not provide an...

DS/ISO 9869-2 - Thermal insulation – Building elements – In-situ measurement of thermal resistance and thermal transmittance – Part 2: Infrared method for frame structure dwelling
August 21, 2018 - DS

This document describes the infrared method for measuring the thermal resistance and thermal transmittance of opaque building elements on existing buildings when observing high emissivity diffuse surface using an infrared (IR) camera. This document demonstrates a screening test by...

GMW14308 - Retractor - Power Spring and Comfort Covers Retention
August 1, 2015 - GMW

Purpose. To measure the retention of the power spring cover to the frame of the retractor. This procedure also may be used to test the retention of any protective or functional cover. Applicability. To all safety belt retractor assemblies.

UL 10B - Standard for Fire Tests of Door Assemblies
February 7, 2008 - ULSE

00010b-000000-000000 1 Scope 1.1 These methods of fire tests are applicable to door assemblies of various materials and types of construction for use in wall openings to retard the passage of fire. 1.2 Tests made in conformity with these test methods register performance during the test...

ATIS 0100513 - Frame Relay Data Communication Service -Access, User Information Transfer, Disengagement, and Availability Performance Parameters
February 1, 2003 - ATIS

Purpose and Scope This standard defines speed, accuracy, dependability, and availability parameters that may be used in specifying and assessing the performance of public frame relay data communication services. The defined parameters apply to end-to-end, point-to-point frame relay...

DS/IEC 62906-5-3 - Laser display devices – Part 5-3: Measuring methods of image quality for laser projection displays
February 8, 2021 - DS

IEC 62906-5-3:2021(E) specifies the standard measurement conditions and measuring methods for determining the parameters of image quality for full-frame laser projection displays integrating the projection devices and screens. The front and rear projection screens are included in this...

IEC 62906-5-3 - Laser display devices – Part 5-3: Measuring methods of image quality for laser projection display
February 1, 2021 - IEC

This document specifies the standard measurement conditions and measuring methods for determining the parameters of image quality for full-frame laser projection displays integrating the projection devices and screens. The front and rear projection screens are included in this...

Structural assessment: the use of full and large scale testing
January 1, 1987 - BRE

These four guides deal with repairs to damage caused by flooding.Part 1 gives advice on cleaning the building in the first few days after the water has receded: such action can reduce the reoccupation time and minimise repairs and replacement.Part 2 deals with the treatment and repair of floors,...

ASTM E2319-22 - Standard Test Method for Determining Air Flow Through the Face and Sides of Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
August 1, 2022 - ASTM International

1.1 This test method is a modified version of Test Method E283/E283M, and provides a standard laboratory procedure for determining air leakage separately through the face and sides of exterior windows, curtain walls, and doors under specified differential pressure conditions across the...

DS/ISO 19467 - Thermal performance of windows and doors – Determination of solar heat gain coefficient using solar simulator
May 2, 2017 - DS

ISO 19467:2017 specifies a method to measure the solar heat gain coefficient of complete windows and doors. ISO 19467:2017 applies to windows and doors a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and...

ISO 19467 - Thermal performance of windows and doors - Determination of solar heat gain coefficient using solar simulator
April 1, 2017 - ISO

This document specifies a method to measure the solar heat gain coefficient of complete windows and doors. This document applies to windows and doors a) with various types of glazing (glass or plastic; single or multiple glazing; with or without low emissivity coatings, and...

Managing CO2 Emissions in the Chemical Industry
January 1, 2011 - WILEY

In this book technical and administrative aspects of CO2 emissions are covered. The book addresses especially the chemical and petrochemical industry. For the reader it will deliver answers to the following questions - How can I measure and demonstrate the CO2 emissions linked to my...

DSF/IEC 62906-5-3 ED1 - Laser display devices – Part 5-3: Measuring methods of image quality for laser projection displays
DS

This document specifies the standard measurement conditions and measuring methods for determining the parameters of image quality for full-frame laser projection displays integrating the projection devices and screens. The front and rear projection screens are included in this...

ASTM E2319-04(2019) - Standard Test Method for Determining Air Flow Through the Face and Sides of Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
January 1, 2019 - ASTM International

1.1 This test method is a modified version of Test Method E283, and provides a standard laboratory procedure for determining air leakage separately through the face and sides of exterior windows, curtain walls, and doors under specified differential pressure conditions across the specimen....

Advertisement