IEC 62262 - Degrees of Protection Provided by Enclosures for Electrical Equipment Against External Mechanical Impacts (IK Code)
February 1, 2002 - IEC

This standard refers to the classification of the degrees of protection provided by enclosures against external mechanical impacts when the rated voltage of the protected equipment is not greater than 72,5 kV. This standard is only applicable to enclosures of equipment...

NEMA 250-IEC 60529 COMPAR - a Brief Comparison of Nema 250 - Enclosures for Electrical Equipment (1000 Volts Maximum) and IEC 60529 - Degrees of Protection Provided by Enclosures (IP Codes)
January 1, 2002 - NEMA

This Publication is intended to provide a brief comparison and explanation of some of the basic differences between NEMA Standard 250, Enclosures for Electrical Equipment (1000 Volts Maximum) and IEC Standard 60529, Degrees of Protection Provided by Enclosures (IP Code)....

DSF/PREN IEC 61969-1 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 1: Design guidelines
DS

This part of IEC 61969 contains design guidelines for outdoor enclosures and is applicable over a wide field of mechanical, electromechanical and electronic equipment and its installation where a modular design is used. The objectives of this standard are - to provide an overview of...

DSF/FPREN IEC 61969-1 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 1: Design guidelines
DS

This part of IEC 61969 contains design guidelines for outdoor enclosures and is applicable over a wide field of mechanical, electromechanical and electronic equipment and its installation where a modular design is used. The objectives of this standard are - to provide an overview of...

DS/EN 13463-2 - Non-electrical equipment indented for use in potentially explosive atmospheres - Part 2: Protection by flow restricting enclosure "fr"
February 4, 2005 - DS

This document specifies the requirements for the construction and testing of flow restricting enclosures for non-electrical equipment intended for use in potentially explosive atmospheres.

DSF/EN 62262/PRA1 - Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
DS

This standard refers to the classification of the degrees of protection provided by enclosures against external mechanical impacts when the rated voltage of the protected equipment is not greater than 72,5 kV. This standard is only applicable to enclosures of equipment...

SNZ AS/NZS 60079.2 - Explosive atmospheres Part 2: Equipment protection by pressurized enclosure ‘p’
December 17, 2015 - SNZ

This part of IEC 60079 contains the specific requirements for the construction and testing of electrical equipment with pressurized enclosures, of type of protection "p", intended for use in explosive gas atmospheres or explosive dust atmospheres. It also includes the...

IEC 60079-2 REDLINE - Explosive atmospheres – Part 2: Equipment protection by pressurized enclosure "p"
July 1, 2014 - IEC

This part of IEC 60079 contains the specific requirements for the construction and testing of electrical equipment with pressurized enclosures, of type of protection "p", intended for use in explosive gas atmospheres or explosive dust atmospheres. It also includes the...

UL 60079-2 - Explosive Atmospheres - Part 2: Equipment Protection by Pressurized Enclosure
June 2, 2017 - ULSE

uliec-60079-2.6 Explosive Atmospheres - Part 2: Equipment Protection by Pressurized Enclosure "p" UL 60079-2 1 Scope 1DV Modification of Clause 1 to replace with the following: This part of IEC 60079 standard contains the specific requirements for the construction and testing of...

DS/EN 13463-3 - Non-electrical equipment for use in potentially explosive atmospheres - Part 3: Protection by flameproof enclosure 'd'
May 2, 2005 - DS

This EN contains requirements for the construction and testing of equipment with type of protection flameproof enclosure, intended for use in potentially explosive atmospheres.

DS/EN IEC 61969-3 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 3: Environmental requirements, tests and safety aspects
August 4, 2020 - DS

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weather protected locations above ground. The purpose of this document is to define a minimum level of environmental performance in...

IEC 61969-3 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 3: Environmental requirements, tests and safety aspects
June 1, 2020 - IEC

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weather protected locations above ground. The purpose of this document is to define a minimum level of environmental performance in...

IEC 61969-3 REDLINE - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 3: Environmental requirements, tests and safety aspects
June 1, 2020 - IEC

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weather protected locations above ground. The purpose of this document is to define a minimum level of environmental performance in...

UL 60079-31 - Explosive Atmospheres - Part 31: Equipment Dust Ignition Protection by Enclosure
June 12, 2015 - ULSE

600790-000310-000000 1 Scope Modification of Clause 1, first and second paragraphs to replace with the following: 1.1 This part of IEC 60079 standard is applicable to electrical equipment protected by enclosure and surface temperature limitation for use in explosive dust...

DSF/FPREN IEC 61969-3 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 3: Environmental requirements, tests and safety aspects
DS

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weatherprotected locations above ground. The purpose of this standard is to define a minimum level of environmental performance in...

DSF/PREN IEC 61969-3 - Mechanical structures for electrical and electronic equipment – Outdoor enclosures – Part 3: Environmental requirements, tests and safety aspects
DS

This part of IEC 61969 specifies a set of basic environmental requirements and tests, as well as safety aspects for outdoor enclosures under conditions of non-weatherprotected locations above ground. The purpose of this standard is to define a minimum level of environmental performance in...

ISO 20653 - Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
February 15, 2013 - ISO

This International Standard applies to degrees of protection (IP code) provided by enclosures of the electrical equipment of road vehicles. It specifies the following: a) Designations and definitions of types and degrees of protection provided by enclosures of...

DS/ISO 20653 - Road vehicles – Degrees of protection (IP code) – Protection of electrical equipment against foreign objects, water and access
March 15, 2013 - DS

This International Standard applies to degrees of protection (IP-Code) provided by enclosures of the electrical equipment of road vehicles. It specifies the following: a) Designations and definitions of types and degrees of protection provided by enclosures of...

DS/EN 60670-24 - Boxes and enclosures for electrical accessories for household and similar fixed electrical installations - Part 24: Particular requirements for enclosures for housing protective devices and other power dissipating electrical equipment
May 22, 2013 - DS

IEC 60670-24:2011 applies to enclosures and parts of them for housing protective devices and other power dissipating electrical equipment intended to be used with a rated voltage not exceeding 400 V and a total incoming load current not exceeding 125 A for household and similar...

DS/EN 60079-31 - Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
July 22, 2014 - DS

IEC 60079-31:2013 is applicable to electrical equipment protected by enclosure and surface temperature limitation for use in explosive dust atmospheres. It specifies requirements for design, construction and testing of electrical equipment and Ex Components. This...