IEC 60336:2020 applies to FOCAL SPOTS in medical diagnostic X-RAY TUBE ASSEMBLIES for medical use, operating at X-RAY TUBE VOLTAGES up to and including 150 kV. This document describes the test methods employing digital detectors for determining: a) FOCAL SPOT dimensions in...
This document specifies the performance and testing of DOSE AREA PRODUCT METERS intended to measure DOSE AREA PRODUCT and/or DOSE AREA PRODUCT RATE to which the PATIENT is exposed during MEDICAL RADIOLOGICAL EXAMINATIONS. This document is applicable to the following types of DOSE AREA...
This European Standard specifies requirements for the design, testing, performance and equipping of road ambulances used for the transport, monitoring, treatment and care of patients. It contains requirements for the patient's compartment in terms of the working environment, ergonomic design...
This document applies to FOCAL SPOTS in medical diagnostic X-RAY TUBE ASSEMBLIES for medical use, operating at X-RAY TUBE VOLTAGES up to and including 150 kV. This document describes the test methods employing digital detectors for determining: a) FOCAL SPOT dimensions in terms...
1.1 This guide provides minimum training standards for Emergency Medical Services (EMS) Ambulance Operators including legal aspects, operator qualifications and testing, history of EMS vehicle operations, vehicle types/equipment, safety, physical forces, mechanics, pre-run,...
This Protocol is intended to cover certification of drug testing sample collection and security equipment, including urine, whole blood, and serum blood sample collection, and encompasses required testing methods, design, and material requirements for this equipment....
This document specifies requirements and test methods for intraoral cameras used in dentistry on patients for pictorial representation of oral cavities in order to support diagnosis and facilitate patient information. It specifies requirements, test methods, instructions for use and...
Scope and object This part of IEC 61223 applies to the performance of MAMMOGRAPHIC X-RAY EQUIPMENT when used in MAMMOGRAPHIC TOMOSYNTHESIS modes of operation, with respect to image quality and dose. Excluded from the scope of this document are: - MAMMOGRAPHIC X-RAY EQUIPMENT modes of...
This document specifies the common requirements for sterilizers used for terminal sterilization of medical devices in health care facilities. This document covers sterilizers that operate with a variety of sterilizing agents (alone or in combination) within a sealed vessel at different...
This document specifies requirements and test methods for intraoral cameras used in dentistry on patients for pictorial representation of oral cavities in order to support diagnosis and facilitate patient information. It specifies requirements, test methods, instructions for use and...
This document applies to X-RAY TUBE ASSEMBLIES and to FILTERING MATERIAL, in medical diagnostic applications up to a HIGH VOLTAGE of 150 kV. For HIGH VOLTAGES greater than 50 kV, this document applies to X-RAY TUBE ASSEMBLIES with tungsten or tungsten-alloy TARGETS only. NOTE 1 The FILTERING...
5.1 Many petroleum products, and some non-petroleum materials, are used as lubricants, and the correct operation of the equipment depends upon the appropriate viscosity of the liquid being used. In addition, the viscosity of many petroleum fuels is important for the estimation of optimum...
5.1 Many petroleum products, and some non-petroleum materials, are used as lubricants, and the correct operation of the equipment depends upon the appropriate viscosity of the liquid being used. In addition, the viscosity of many petroleum fuels is important for the estimation of optimum...
5.1 Many petroleum products, and some non-petroleum materials, are used as lubricants, and the correct operation of the equipment depends upon the appropriate viscosity of the liquid being used. In addition, the viscosity of many petroleum fuels is important for the estimation of optimum...
This part of IEC 61223 applies to CT SCANNERS that conform to IEC 60601-2-44:2009, IEC 60601-2-44:2009/AMD1
1.1 This test method covers visual and dimensional inspection and test for scale accuracy to be used in the verification of liquid-in-glass thermometers as specified in Specifications E1 and E2251. However, these procedures may be applied to other liquid-in-glass thermometers.2 Note...
This book provides an exam-focused revision guide to both anaesthetic and surgical instruments. This is a comprehensive guide to passing an exam station and includes commonly tested knowledge. The Anaesthetic section includes airway, breathing, circulation and analgesia equipment....
This document specifies requirements for setting a uniform procedure to verify the effectiveness of the protective measures for current-using equipment or appliances after they have been repaired. This procedure is applicable to current-using equipment or appliances with a rated...
This document specifies the common requirements for sterilizers used for terminal sterilization of medical devices in health care facilities. This document covers sterilizers that operate with a variety of sterilizing agents (alone or in combination) within a sealed vessel at different...