019890-000000-000000
1.1 This guide is intended to identify and define the minimum requirements for the best practices in the design, installation, and application of Type C portable tanks in marine liquefied natural gas (LNG) fuel tank service used on LNG-fueled vessels. 1.2 This guide comprises the necessary...
1.1 This test method covers the use of a portable refractometer for determining the approximate freezing protection provided by ethylene and propylene glycol-based coolant solutions as used in engine cooling systems and special applications. Note 1: Some instruments have a supplementary...
5.1 Liquid penetrant testing methods indicate the presence, location, and to a limited extent, the nature and magnitude of the detected discontinuities. Each of the various penetrant methods has been designed for specific uses such as critical service items, volume of parts, portability, or...
1.1 These test methods2 cover procedures and definitions for the mechanical testing of steels, stainless steels, and related alloys. The various mechanical tests herein described are used to determine properties required in the product specifications. Variations in testing methods are to be...
This Aerospace Information Report provides general information to aircraft designers and engineers, regarding LOX, its properties, its storage and its conversion to gas. Much useful information is included herein for aircraft designers regarding important design considerations for a safe and...
00962a-000000-000000
4.1 The Barcol Impressor is portable and therefore useful for in situ determination of the hardness of fabricated parts and individual test specimens for production control purposes. 4.2 This test method should be used only as cited in applicable material specifications.
1.1 This test method covers the determination of the Brinell hardness of metallic materials by the Brinell indentation hardness principle. This standard provides the requirements for a Brinell testing machine and the procedures for performing Brinell hardness tests. 1.2 This test method includes...
013630-000000-000000
3.1 Portable hardness testers are used for testing materials that because of their size, location or other requirements such as test point are unable to be tested using traditional fixed instruments. 3.2 Portable hardness testers, by their nature, induce variation that could influence...
4.1 The Webster hardness gage is portable and therefore useful for in situ determination of the hardness of fabricated parts and individual test specimens for production control purposes. It is not as sensitive as Rockwell or Brinell hardness machines; see 10.2. 4.2 This test method should...
4.1 Static Load Test-This test verifies that the portable high anchor device can support the design load without permanent deformation and continue to function in a safe manner. 4.2 Load Test for Failure-This test determines the force at which the portable high anchor device fails.
1.1 This standard applies to design, manufacture, installation, operation, maintenance, and inspection of permanent amusement railway ride(s) that have a track gauge greater than or equal to 12 in. (305 mm) measured between the heads of the rails and their related devices and facilities, for...
1.1 This practice applies to operations of amusement railway ride(s) that have a track gauge greater than or equal to 12 in. (305 mm) measured between the heads of the rails. This excludes patron powered ride vehicles specifically designed for children. 1.2 This standard does not apply to the...
This specification is used to standardize the portable water heaters used on personnel decontamination lines to insure the heaters provide sufficient heated water for as long as they are needed during the emergency. The heater materials of construction shall be easily cleaned of surface mud...
1.1 This specification is used to standardize the portable air heaters used on personnel decontamination lines to insure the heaters provide sufficient heated air for personnel comfort before, during, and after the decontamination for as long as they are needed during the emergency. Note 1:...