loading
TM 5-805-13 - RAISED FLOOR SYSTEMS
ARMY
A description is not available for this item.
AFM 88-4 C9 - RAISED FLOOR SYSTEMS
AF
A description is not available for this item.
UFGS-10270A - RAISED FLOOR SYSTEM
ARMY
A description is not available for this item.
DS/EN 12825 - Raised access floors
September 27, 2001 - DS

This Standard specifies the characteristics and performance requirements of raised access floors for which the main intended use is the internal fitting out of buildings, providing full access for the services to the plenum.

JIS A 1450 - Test methods for raised access floor
July 21, 2015 - JSA

This Japanese Industrial Standard specifies the test methods for raised access floor (hereafter referred to as "floor").

BS EN 12825 - Raised Access Floors
November 22, 2001 - BSI
A description is not available for this item.
DIN EN 12825 - Raised access floors; English version of DIN EN 12825
April 1, 2002 - DIN
A description is not available for this item.
Industrial platform floors: mezzanine and raised storage
April 1, 1999 - BRE

This Digest has been prepared in response to difficulties being experienced with the design and Building Regulation control of mezzanine raised storage platform floors. It aims to ease such difficulties by providing specific authoritative guidance on these specialised structures which...

VDI 3762 - Sound insulation by means of raised access floors and hollow floors
January 1, 2012 - DIN
A description is not available for this item.
DS/EN 1366-6 - Fire resistance test for service installations - Part 6: Raised access and hollow core floors
November 29, 2004 - DS

This part of EN 1366 specifies a method for determining the fire resistance of raised access floors and hollow floors when subjected to a fire from within the plenum beneath the floor.

MIL-F-46048 - FLOOR PLATE, RAISED PATTERN, MAGNESIUM ALLOY (AZ31B),ROLLED
NPFC
A description is not available for this item.
ASHRAE 90477 - UFAD O&M GUIDE A Practical Guide for Operation and Maintenance of Underfloor Air Distribution Systems
January 1, 2016 - ASHRAE

Introduction Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of an HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a...

DS/EN 13264 - Ventilation for buildings - Floor mounted air terminal devices - Tests for structural classification
July 17, 2001 - DS

This European Standard specifies structural classifications for floor mounted Air Terminal Devices (ATD's) in respect of their possible applications and the following related structural test methods: a) Static test methods. b) Impact test methods. c) Dynamic test methods. Electrical...

APA L110 - Case Study: Murray House
February 1, 2011 - APA

This case study features the construction of owner/builder Scott Murray's raised wood floor home in St. Augustine, Florida. Murray wanted a home with height and curb appeal. He chose to forego the slab-on-grade construction typical for Florida in favor of a raised wood...

BS EN 1366-6 - Fire resistance tests for service installations Part 6: Raised access and hollow core floors
November 18, 2004 - BSI
A description is not available for this item.
DIN EN 13501-2 - Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
December 1, 2016 - DIN

This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application...

DS/EN 13501-2 - Fire classification of construction products and building elements – Part 2: Classification using data from fire resistance tests, excluding ventilation services
September 22, 2016 - DS

This European Standard specifies the procedure for classification of construction products and building elements using data from fire resistance and smoke leakage tests which are within the direct field of application of the relevant test method. Classification on the basis of extended application...

Advertisement