1.1 This practice provides ergonomic design criteria from a human-machine perspective for the design and construction of maritime vessels and structures and for equipment, systems, and subsystems contained therein, including vendor-purchased hardware and software. 1.1.1 The focus of these design...
5.1 This practice is intended to promote the use of trained telecommunicators in the role of emergency medical dispatcher. It defines the basic skills and medical knowledge to permit understanding and resolution of the problems that constitute their daily routine. To use trained telecommunicators...
02735c-000000-000000
1.1 This practice provides ergonomic design criteria from a human-machine perspective for the design and construction of maritime vessels and structures and for equipment, systems, and subsystems contained therein, including vendor-purchased hardware and software. 1.1.1 The focus of these design...
4.1 The Use of this Standard Guide-This guide addresses issues related solely to adaptation strategies and development of a plan to address extreme weather and related physical changes. This guide does not include specific guidance on risk assessment, however references are provided in Appendix X3....
004670-000000-000000
This consumer safety specification covers performance requirements, test methods, and labeling requirements to promote the safe use of baby changing tables and other changing surfaces such as contoured changing pads and add-on changing units that are sold separately for use on furniture products...
1.1 This standard practice describes procedures for evaluating indoor air quality (IAQ) concerns in residential buildings. 1.2 The practice primarily addresses IAQ concerns encountered in single-family detached and attached (for example, townhouse or duplex design) residential buildings. Limited...
The Scope of this Technical Report is an analysis of the impacts of applying Secure Telephone Identity Revisited (STIR), as specified in RFC 8224 Authenticated Identity Management in the Session Initiation Protocol (SIP) [Ref 1] and Signature-based Handling of Asserted Information Using...
5.1 This test method establishes the requirements for a standardized method of evaluating the performance of crimped-type electrical connections having solid or stranded conductors. 5.2 In order to achieve a successful crimped connection, the crimping tool must deform the material of the crimp...
This document provides formal procedures and two, alternative, methods (users are advised to choose whichever of the two suits their individual requirements) for determining the priority of on-board messages presented to drivers of road vehicles by transport information and control systems (TICS)...
1.1 This practice provides ergonomic design criteria from a human-machine perspective for the design and construction of maritime vessels and structures and for equipment, systems, and subsystems contained therein, including vendor-purchased hardware and software. 1.1.1 The focus of these design...
This module specifies the requirements for the maintenance of the BT IP Trade Turret and backup telephone. It applies to all staff carrying out maintenance of the BT Trader Turret. Purpose The purpose of this module is to reduce the risk of malfunction through wear and tear by providing a...
1.1 This specification covers "iron" wire with Class A, Class B, and Class C zinc coatings, suitable for use in telephone, telegraph, and signal transmission. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only. 1...
This module applies to the maintenance, and those undertaking it, of Whiteley PETS, charger & batteries where used as Public Emergency Telephone Systems at road/rail crossings on Network Rail infrastructure. The maintenance of the telephones is covered by standard NR/L3/TEL/30181/011.
This instruction applies to all staff engaged in the maintenance and testing of all lineside assets (such as Signal Post Telephones, Crossing Telephones etc) and operational building telephones. For the purposes of this instruction an operational building shall include: - •...
This document specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels...
Call completion/call termination in today's Public Switched Telephone Network (PSTN)1 depends on coordination between different service provider (SP) entities, each playing their part in setting up a workable connection between calling and called parties. As the PSTN has evolved through the...
This document specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels...