UL 508A - Industrial Control Panels
April 24, 2018 - ULSE

00508a-000000-000000 1 Scope 1.1 These requirements cover industrial control panels intended for general industrial use, operating from a voltage of 1000 volts or less. This equipment is intended for installation in ordinary locations, in accordance with the National Electrical Code, ANSI/NFPA 70,...

UL 1637 - Home Health Care Signaling Equipment
September 21, 2017 - ULSE

016370-000000-000000 1 Scope 1.1 These requirements cover the individual units that comprise a home health care system intended for use in ordinary indoor residential locations. 1.2 These requirements also cover a complete home health care system in which a signal initiating device (both routine...

DEF STAN 61-12: PT12 SEC2 - Wires, Cords and Cables Electrical Metric Units Part 12 Section 2: Cables, Telephone (Internal for Switchboard, Distribution & Jumper Wiring)
July 23, 2010 - MODUK

This Defence Standard (Def Stan) specifies telephone cables (internal) which are to be utilised in telephone, telegraph and allied systems for Ministry of Defence use. Service requirements for telephone cables (external) are specified in Def Stan 61-12 Part 12 Section 1. Table...

TIA-1063 - Telecommunications User Premises Equipment Analog Telephone Port Requirements for Packet-based User Premises Terminal Adapters
August 5, 2015 - TIA

This standard establishes performance and technical criteria for interfacing the analog telephone port of a terminal adapter with analog telephony equipment. It defines the electrical and telephony aspects (e.g., DTMF receiver and call progress signal generation) of the loop start analog...

UL 514D - Cover Plates for Flush-Mounted Wiring Devices
June 28, 2013 - ULSE

00514d-000000-000000 1 Scope 1.1 This standard applies to metallic and nonmetallic cover plates and associated gaskets for flush-mounted wiring devices intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, CSA C22...

DS/HD 60364-7-714 - Low-voltage electrical installations – Part 7-714: Requirements for special installations or locations – External lighting installations
November 5, 2015 - DS

IEC 60364-7-714:2011 applies to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply authority or the origin of the circuit...

CSA C22.2 NO 42.1 - Cover plates for flush-mounted wiring devices
January 1, 2013 - CSA

This standard applies to metallic and nonmetallic cover plates and associated gaskets for flush-mounted wiring devices intended for installation in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, CSA C22.1, General Requirements - Canadian...

EIA IEB 15 - Provision of Premises Wiring for One and Two Line Voice Telephone Systems
January 1, 1983 - TIA

This document contains minimum technical, material, and workmanship requirements applicable to the provision of premises wiring for connection to basic telephone. exchange service. This Engineering Bulletin does not address wiring from one building to another or cable...

ICEA S-101-699 - CATEGORY 3 INDIVIDUALLY UNSHIELDED TWISTED PAIR INDOOR CABLE FOR USE IN GENERAL PURPOSE NON-LAN TELECOMMUNICATION WIRING SYSTEMS TECHNICAL REQUIREMENTS
March 1, 2012 - ICEA

This Standard covers mechanical, electrical and flammability requirements for thermoplastic insulated and jacketed, copper conductor, inside wiring cables intended primarily for general purpose communication applications in telephone company central offices or on consumer premises in...

ITU-R REPORT SM.2158 - Impact of power line telecommunication systems on radiocommunication systems operating in the LF, MF, HF and VHF bands below 80 MHz
June 1, 2011 - ITU-R

Introduction As part of the studies on the compatibility between radiocommunication systems and high data rate telecommunication systems using electricity power supply or telephone distribution wiring (Question ITU-R 221/1), this Report covers the use of the radio spectrum and...

IEC 60364-7-714 - Low-voltage electrical installations – Part 7-714: Requirements for special installations or locations – External lighting installations
December 1, 2011 - IEC

The particular requirements of this part of IEC 60364 apply to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply...

ITU-R REPORT SM.2212 - Impact of power line telecommunication systems on radiocommunication systems operating in the VHF and UHF bands above 80 MHz
June 1, 2011 - ITU-R

Introduction As part of the studies on the compatibility between radiocommunication systems and high data rate telecommunication systems using electricity power supply or telephone distribution wiring (Question ITU-R 221/1), this Report covers the use of the radio spectrum and...

TIA-1096 - Telecommunications Telephone Terminal Equipment Connector Requirements for Connection of Terminal Equipment to the Telephone Network
March 17, 2008 - TIA

The technical criteria in this standard are intended to protect the telephone network from the harms defined by the Federal Communications Commission (FCC) Part 68, Section 3 rules in Title 47 of the Code of Federal Regulations (47 CFR 68.3). This standard specifies physical dimensions,...

BS 4808-1 - Specification for L.F. cables and wires with PVC insulation and PVC sheath for telecommunication - Part 1: General requirements and tests
March 14, 1972 - BSI

Gives the general requirements and test methods for a range of low frequency cables and equipment wires for use inside telephone exchanges and for the internal wiring of electronic and other equipment.

BS 4808-5 - Specification for L.F. cables and wires with PVC insulation and PVC sheath for telecommunication. Part 5: Cables with solid or stranded conductors, screened and sheathed, one pair
November 23, 1973 - BSI

Gives details of the construction, dimensions and requirements for screened and sheathed single pair cables. Examples of usage are inside telephone and telegraph exchanges and the internal wiring of electronic and other equipment.

UL 497B - Protectors for Data Communications and Fire-Alarm Circuits
June 14, 2004 - ULSE

00497b-000000-000000 1 Scope 1.1 These requirements cover protectors for data communications and fire-alarm circuits. 1.2 As covered by these requirements, data communications circuit protectors and fire-alarm circuit protectors consist of single- and multiple-pair air-gap arresters, gas-tube...

BS 4808-3 - Specification for L.F. cables and wires with PVC insulation and PVC sheath for telecommunication. Part 3: Cables and equipment wires, with solid or stranded conductors, screened , single
August 31, 1972 - BSI

Gives details of construction, dimensions and requirements for screened cables and screened equipment wire, all with a single solid or stranded conductor and PVC insulation. Examples of usage are inside telephone and telegraph exchanges and the internal wiring of electronic and other...