1.1 This test method covers a laboratory procedure for determining the ability of a waterproofing membrane to bridge a crack in the substrate. 1.2 There are no ISO standards similar or equivalent to this ASTM standard. 1.3 The values stated in either SI units or inch-pound units are to be...
1.1 This guide describes the design and installation of cold liquid-applied elastomeric waterproofing membrane systems that have an integral wearing surface. The cold liquid-applied elastomeric waterproofing membrane (membrane) to which this guide refers is specified in Specification...
5.1 This test method is used as a screening tool to determine the hydrostatic pressure to which a liquid-applied waterproofing membrane may be subjected without failing when stretched over a crack in the substrate. This test method discriminates between a membrane that is very resistant to...
1.1 This specification covers asphaltic primer suitable for use with asphalt in roofing, dampproofing, and waterproofing below or above ground level, for application to concrete, masonry, metal, and asphalt surfaces. 1.2 The values stated in either SI units or inch-pound units are to be...
This specification covers three types of deck waterproofing membrane systems designed for use on bridge decks which will receive an asphaltic concrete overlay. Type I are cold liquid-applied chemically curing membrane materials that that require a membrane protection course. Type II, on the...
5.1 Roofing and waterproofing materials and systems undergo changes in physical properties as a result of being subjected to heat. They also undergo changes in physical properties as they age in service. Since service conditions vary widely, any relationship between changes observed in this...
1.1 This guide covers the use of waterstops within cast-in-place concrete construction. Waterstops are generally placed within static, non-moving construction joints in concrete to close off the joint to water, which may be under significant hydrostatic pressure. They are used as part of the...
4.1 This practice provides a guide for factors to be considered prior to waterproofing bridge decks with water barrier membrane systems. It will provide guidance for specification of materials, application of membrane systems, and placement of asphalt wearing courses. It may be used as a...
1.1 This specification covers a mixture of processed coal tar base with or without mineral fillers or polymer modification suitable for brush, spray, and squeegee application to coal tar built-up and coal tar modified bitumen membrane roofing, flashings, dampproofing, insulations, and...
This specification deals with molds for forming concrete test cylinders vertically. Molds shall be constructed in the form of right circular cylinders and have a nominal inside height equal to twice the nominal inside diameter. The following are types of molds covered: reusable molds and single-use...
This specification covers asphalt-saturated organic felt used in roofing and waterproofing. Two types of asphalt-saturated felts are presented: type I - commonly called No. 15 asphalt felt, and type II - commonly called No. 30 asphalt felt. In the process of manufacture a single thickness of...
This practice covers material, workmanship, and construction procedures for applying surface bonded mortar to both sides of dry stacked concrete masonry units. Mortar shall be mixed and shall be selected in accordance with the proportion specification prescribed. Shims shall be corrosion-resistant.
5.1 Since felts or sheet roofing or waterproofing materials are brought to the roof in a roll and unrolled, this test method simulates felt or membrane behavior under actual field conditions during the unrolling process. 5.2 This test method is designed to aid those interested in the...
5.1 Dynamic mechanical analysis provides a measure of the rheological properties of roofing and waterproofing membrane materials. 5.2 Thermogravimetry is used to characterize the thermal stability of roofing and waterproofing membrane materials under the specific temperature program...
5.1 This test method is designed to aid those interested in the engineering properties of roofing and waterproofing sheet materials and membranes. 5.2 This test method enables a researcher to measure the relative flexibility of roofing and waterproofing sheet materials and membranes...
1.1 This specification covers prefabricated modified bituminous sheet materials with glass fiber reinforcement, which use atactic polypropylene (APP) as the primary modifier and which are intended for use as a base sheet in the fabrication of multiple ply roofing and waterproofing membranes....
1.1 This practice describes test conditions and procedures for fluorescent UV and condensation exposures conducted according to Practices G151 and G154 for bituminous roofing and waterproofing materials. (See Terminology G113.) 1.2 The values stated in either SI units or inch-pound units are...
1.1 This specification covers fiberglass reinforced modified bituminous sheet materials that use styrene-butadiene-st