scope:
This code applies to commercial buildings and the buildings' sites and associated systems and equipment.
Exception:
The Energy Code shall not apply to any of the following, provided that the energy use of the building is not increased:
Storm windows installed over existing fenestration;
Glass only replacements in an existing sash and frame;
Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled with insulation;
Construction where the existing roof, wall or floor cavity is not exposed;
Reroofing for roofs where neither the sheathing nor the insulation is exposed; roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing shall be insulated either above or below the sheathing;
Replacement of existing doors that separate conditioned space from the exterior shall not require the installation of a vestibule or revolving door, provided, however, that an existing vestibule that separates such conditioned space from the exterior shall not be removed;
Alterations that replace less than fifty percent of the luminaries in a space, provided that such alterations do not increase the installed interior lighting power; or alterations that replace only the bulb and ballast within the existing luminaries in a space provided that the alteration does not increase the installed interior lighting power.