DS/IEC/IEEE 62271-37-013

High-voltage switchgear and controlgear - Part 37-013: Alternating-current generator circuit-breakers

active, Most Current
Buy Now
Organization: DS
Publication Date: 20 November 2015
Status: active
Page Count: 224
ICS Code (High voltage switchgear and controlgear): 29.130.10
scope:

IEC/IEEE 62271-37-013:2015(E) is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applications, and their requirements are not completely covered by this standard. This standard is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment. This standard has been prepared by a joint working group comprised of members both from IEC 17A/WG 52 representing subcommittee 17A: High-voltage switchgear and controlgear, of IEC technical committee 17: Switchgear and controlgear, in cooperation with IEEE WG P62271-37-013 representing the Switchgear Committee of the Power and Energy Society of the IEEE, under the IEC/IEEE Dual Logo Agreement.

Document History

October 25, 2021
High-voltage switchgear and controlgear – Part 37-013: Alternating current generator circuit-breakers
IEC/IEEE 62271-37-013:2021 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for...
High-voltage switchgear and controlgear – Part 37-013: Alternating-current generator circuit-breakers
IEC/IEEE 62271-37-013:2015(E) is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and...
DS/IEC/IEEE 62271-37-013
November 20, 2015
High-voltage switchgear and controlgear - Part 37-013: Alternating-current generator circuit-breakers
IEC/IEEE 62271-37-013:2015(E) is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and...
High-voltage switchgear and controlgear – Part 37-013: Alternating-current generator circuit-breakers
This part of IEC 62271 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for...
IEC/IEEE 62271-37-013 Ed.1: High-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers
This part IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for...
High-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers
This part IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for...