CEI EN 62304

Medical device software - Software life-cycle processes

active, Most Current
Buy Now
Organization: CEI
Publication Date: 1 April 2016
Status: active
Page Count: 50
ICS Code (Medical equipment): 11.040
scope:

* Field of application

Replace the entire existing text of this subclause with the following:

This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE when software is itself a MEDICAL DEVICE or when software is an embedded or integral part of the final MEDICAL DEVICE.

NOTE 1 This standard can be used in the development and maintenance of software that is itself a medical device. However, additional development activities are needed at the system level before this type of software can be placed into service. These system activities are not covered by this standard, but can be found in IEC 82304- 11 [22].

This standard describes PROCESSES that are intended to be applied to software which executes on a processor or which is executed by other software (for example an interpreter) which executes on a processor.

This standard applies regardless of the persistent storage device(s) used to store the software (for example: hard disk, optical disk, permanent or flash memory).

This standard applies regardless of the method of delivery of the software (for example: transmission by network or email, optical disk, flash memory or EEPROM). The method of software delivery itself is not considered MEDICAL DEVICE SOFTWARE.

This standard does not cover validation and final release of the MEDICAL DEVICE, even when the MEDICAL DEVICE consists entirely of software.

NOTE 2 If a medical device incorporates embedded software intended to be executed on a processor, the requirements of this standard apply to the software, including the requirements concerning software of unknown provenance (see 8.1.2).

NOTE 3 Validation and other development activities are needed at the system level before the software and medical device can be placed into service. These system activities are not covered by this standard, but can be found in related product standards (e.g., IEC 60601-1, IEC 82304-1, etc.).

1 In preparation.

 

Document History

CEI EN 62304
April 1, 2016
Medical device software - Software life-cycle processes
* Field of application Replace the entire existing text of this subclause with the following: This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE when software is...
August 1, 2015
Medical device software - Software life-cycle processes
Purpose This standard defines the life cycle requirements for MEDICAL DEVICE SOFTWARE. The set of PROCESSES, ACTIVITIES, and TASKS described in this standard establishes a common framework for...
October 1, 2006
Medical device software - Software life-cycle processes
La Norma definisce le prescrizioni relative al ciclo di vita del software per dispositivi medici. I processi, attività e compiti descritti in essa costituiscono una struttura comune per i processi...