ASTM International - ASTM D5011-17

Standard Practices for Calibration of Ozone Monitors Using Transfer Standards

active
Buy Now
Organization: ASTM International
Publication Date: 1 October 2017
Status: active
Page Count: 29
ICS Code (Air quality in general): 13.040.01
significance And Use:

5.1 The reactivity and instability of O3 precludes the storage of O3 concentration standards for any practical length of time, and precludes direct certification of... View More

scope:

1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards.

1.2 These practices describe five types of transfer standards:

Practice A-Analytical instruments,

Practice B-Boric acid potassium iodide (BAKI) manual analytical procedure,

Practice C-Gas phase titration with excess nitric oxide,

Practice D-Gas phase titration with excess ozone, and

Practice E-Ozone generator device.

1.3 These practices describe procedures to establish the authority of transfer standards: qualification, certification, and periodic recertification.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM D5011-17
October 1, 2017
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: Practice...
March 1, 2009
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
The reactivity and instability of O3 precludes the storage of O3 concentration standards for any practical length of time, and precludes direct certification of O3 concentrations as SRM's. Moreover,...
April 10, 2003
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: (A)...
September 10, 1997
Standard Practices for Calibration of Ozone Monitors Using Transfer Standards
1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards. 1.2 These practices describe five types of transfer standards: (A)...