CSA IEC 61000-4-28

Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test

active, Most Current
Buy Now
Organization: CSA
Publication Date: 1 January 2001
Status: active
Page Count: 33
scope:

This part of IEC 61000 is a basic EMC (electromagnetic compatibility) publication. It considers immunity tests for electric and/or electronic equipment in its electromagnetic environment. Only conducted phenomena are considered, including immunity tests for equipment connected to public and industrial networks.

The object of this part is to establish a reference for evaluating the immunity of electric and electronic equipment when subjected to variations of the power frequency.

This standard applies to electric and/or electronic equipment connected to 50 Hz or 60 Hz distributed network with rated line current up to 16 A per phase. It does not apply to electric and/or electronic equipment connected to a.c. 400 Hz distribution networks. Tests concerning these networks will be covered by other IEC standards.

In general, electrical and electronic equipment is not susceptible to minor variations of the power frequency. Testing according to this standard should be limited to products which are assessed to be susceptible to power frequency variations by virtue of design, environment or failure consequences.

The immunity test levels required for a specific electromagnetic environment together with the performance criteria are indicated in the product, product family or generic standards as applicable.

Document History

Amendment 2 Electromagnetic compatibility (EMC) - Part 4-28: Testing and measurement techniques - Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
A description is not available for this item.
Amendment 2 Electromagnetic compatibility (EMC) — Part 4-28: Testing and measurement techniques — Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
A description is not available for this item.
Electromagnetic compatibility (EMC) — Part 4-28: Testing and measurement techniques — Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
A description is not available for this item.
January 1, 2010
Amendment 2 Electromagnetic compatibility (EMC) - Part 4-28: Testing and measurement techniques - Variation of power frequency, immunity test for equipment with input current not exceeding 16 A per phase
FOREWORD This amendment has been prepared by subcommittee 77A: Low-frequency phenomena, of IEC technical committee 77: Electromagnetic compatibility. Full information on the voting for the approval...
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
A description is not available for this item.
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
A description is not available for this item.
Electromagnetic compatibility (EMC) — Part 4-28: Testing and measurement techniques — Variation of power frequency, immunity test
A description is not available for this item.
Amendment 1 Electromagnetic compatibility (EMC) – Part 4-28: Testing and measurement techniques – Variation of power frequency, immunity test
A description is not available for this item.
January 1, 2003
Amendment 1 Electromagnetic compatibility (EMC) – Part 4-28: Testing and measurement techniques – Variation of power frequency, immunity test
FOREWORD This amendment has been prepared by subcommittee 77B: High frequency phenomena, of IEC technical committee 77: Electromagnetic compatibility. Full information on the voting for the...
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
This part of IEC 61000 is a basic EMC (electromagnetic compatibility) publication. It considers immunity tests for electric and/or electronic equipment in its electromagnetic environment. Only...
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
A description is not available for this item.
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
A description is not available for this item.
Electromagnetic compatibility (EMC) — Part 4-28: Testing and measurement techniques — Variation of power frequency, immunity test
This part of IEC 61000 is a basic EMC (electromagnetic compatibility) publication. It considers immunity tests for electric and/or electronic equipment in its electromagnetic environment. Only...
CSA IEC 61000-4-28
January 1, 2001
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
This part of IEC 61000 is a basic EMC (electromagnetic compatibility) publication. It considers immunity tests for electric and/or electronic equipment in its electromagnetic environment. Only...
Electromagnetic Compatibility (EMC) - Part 4-28: Testing and Measurement Techniques - Variation of Power Frequency, Immunity Test
A description is not available for this item.

References