DSF/prEN 12619

Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method

pending
Organization: DS
Status: pending
Page Count: 22
ICS Code (Stationary source emissions): 13.040.40
scope:

The method specified in this European Standard is designed for use as a standard reference method. This European Standard specifies a set of minimum performance requirements for an instrument using flame ionization detection, together with procedures for its calibration and operation, for the measurement of the mass concentration of total gaseous organic carbon (TOC) and for solvent emissions total volatile organic compounds (TVOC) in stationary source emissions. This European Standard is suitable for the measurement of gaseous or vapour phase TOC and TVOC emissions such as emissions from waste incinerators and solvent using processes. The results obtained using this standard, are expressed in milligrams per cubic metre as total carbon (mg/m³). This standard is suitable for use in the range 1 mg/m³ up to at least 1000 mg/m³. This European Standard is not applicable for permanently installed AMS. For permanently installed AMS refer to EN 15267-3. NOTE This method can also be used also for higher mass concentrations TVOC.

Document History

February 8, 2013
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous...
August 16, 1999
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon at low concentrations in flue gases - Continuous flame ionisation detector method
This European Standard specifies a set of minimum performance requirements for an instrument using Flame Ionisation Detection (FID), together with procedures for its calibration and operation, for...
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
The flame ionisation detector (FID) method specified in this European Standard is for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic...
DSF/prEN 12619
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
The method specified in this European Standard is designed for use as a standard reference method. This European Standard specifies a set of minimum performance requirements for an instrument using...