DSF/FprEN 12619

Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method

pending
Organization: DS
Status: pending
Page Count: 23
ICS Code (Stationary source emissions): 13.040.40
scope:

The flame ionisation detector (FID) method specified in this European Standard is for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic substances (expressed as TVOC) in stationary source emissions (e.g. emissions from waste incinerators and solvent using processes, emission measurements according to 2010/75/EU) in the concentration range up to 1000 mg/m³. This European Standard specifies the requirements for an instrument using flame ionisation detection, together with procedures for its operation. The results obtained using this standard, are expressed in milligrams per cubic metre (mg/m³) as total carbon (TVOC). This European Standard is not applicable for permanently installed automated measuring systems (AMS). Alternative methods to this method may be used provided that the user can demonstrate equivalence, based on the principles of CEN/TS 14793.

Document History

February 8, 2013
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
This European Standard specifies a flame ionisation detector (FID) method. It is intended for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous...
August 16, 1999
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon at low concentrations in flue gases - Continuous flame ionisation detector method
This European Standard specifies a set of minimum performance requirements for an instrument using Flame Ionisation Detection (FID), together with procedures for its calibration and operation, for...
DSF/FprEN 12619
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
The flame ionisation detector (FID) method specified in this European Standard is for use as a standard reference method for the measurement of the mass concentration of gaseous and vaporous organic...
Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
The method specified in this European Standard is designed for use as a standard reference method. This European Standard specifies a set of minimum performance requirements for an instrument using...