DS/EN 55011

Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement

active, Most Current
Buy Now
Organization: DS
Publication Date: 10 March 2020
Status: active
Page Count: 6
ICS Code (Emission): 33.100.10
scope:

CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.<br /><br /> CISPR 11:2015 applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy. This standard covers emission requirements related to radio-frequency (RF) disturbances in the frequency range of 9 kHz to 400 GHz. Measurements need only be performed in frequency ranges where limits are specified in Clause 6. For ISM RF applications in the meaning of the definition found in the ITU Radio Regulations (see Definition 3.13), this standard covers emission requirements related to radio-frequency disturbances in the frequency range of 9 kHz to 18 GHz. Requirements for ISM RF lighting equipment and UV irradiators operating at frequencies within the ISM frequency bands defined by the ITU Radio Regulations are contained in this standard. Equipment covered by other CISPR product and product family emission standards are excluded from the scope of this standard. This sixth edition cancels and replaces the fifth edition published in 2009 and its Amendment 1 published in 2010. It constitutes a technical revision. It introduces and permits type testing on components of power electronic equipment, systems and installations. Its emission limits apply now to low voltage (LV) a.c. and d.c. power ports, irrespective of the direction of power transmission. Several limits were adapted to the practical test conditions found at test sites. They are also applicable now to power electronic ISM RF equipment used for wireless power transfer (WPT), for instant power supply and charging purposes. The limits in the ra ...

Document History

April 13, 2021
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to...
DS/EN 55011
March 10, 2020
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement
CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all...
May 16, 2017
Industrial, scientific and medical equipment – Radio frequency disturbance characteristics – Limits and methods of measurement – Amendment 1 – Measurement of radiated disturbances – Introduction of the FAR for use with CISPR 11 and determination of limits
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to...
April 19, 2016
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all...
August 30, 2010
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
Add the following note at the end of Clause 1: NOTE - Induction cooking appliances are in the process of being transferred from CISPR 11 to CISPR 14-1. Until the removal of induction cooking...
December 7, 2009
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to...
May 24, 2007
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
The limits and methods of measurement laid down in this International Standard apply to industrial, scientific and medical (ISM) equipment, and to electro-discharge machining (EDM) and arc welding...
May 24, 2007
Industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
The limits and methods of measurement laid down in this International Standard apply to industrial, scientific and medical (ISM) equipment, and to electro-discharge machining (EDM) and arc welding...
November 13, 2002
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement
The limits and methods of measurement laid down in this publication apply to industrial, scientific and medical (ISM) equipment as defined in Clause 2, and to spark erosion equipment. Procedures are...
December 23, 1999
Industrial, scientific and medical (ISM) radio-frequency equipment - Radio disturbance characteristics - Limits and methods of measurement
The limits and methods of measurement laid down in this international standard apply to industrial, scientific and medical (ISM) equipment as defined in Clause 2, and to spark erosion equipment....
August 14, 1998
Industrial, scientific and medical (ISM) radio-frequency equipment. Radio disturbance characteristics - Limits and methods of measurement
The limits and methods of measurement laid down in this publication apply to industrial, scientific and medical (ISM) equipment as defined in Clause 2, and to spark erosion equipment. Procedures are...
October 22, 1997
Limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment
The limits and methods of measurement laid down in this publication apply to industrial, scientific and medical (ISM) equipment as defined in Clause 3, and spark erosion equipment. Procedures are...
May 1, 1997
Limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment
The limits and methods of measurement laid down in this publication apply to industrial, scientific and medical (ISM) equipment as defined in Clause 3, and spark erosion equipment. Procedures are...
November 2, 1994
Limits and methods of measurement of radio disturbance characteristics of industrial, scientific and medical (ISM) radio-frequency equipment
The limits and methods of measurement laid down in this publication apply to industrial, scientific and medical (ISM) equipment as defined in Clause 3, and spark erosion equipment. Procedures are...
Industrial, scientific and medical equipment – Measurement of radiated disturbances – Improvement of repeatability for measurements in the frequency range 1-18 GHz
CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all...
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement – Amendment 2: Requirements for semiconductor power converters (SPC)
CISPR 11:2015 is available as <a href="https://webstore.iec.ch/publication/22635">CISPR 11:2015 RLV</a> which contains the International Standard and its Redline version, showing all...
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – limits and methods of measurement
Deletion of the annexes dealing with Statistical assessment of series produced equipment. This Common Modification will cover the base document of EN 55011:2016 + A1 ;amp; A2 (from CISPR) + A11:2020...
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
A description is not available for this item.
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement - Fraction project f4: General maintenance (GM) for CISPR 11 Ed.5.1 (2010)
A description is not available for this item.
Industrial scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement
A description is not available for this item.
Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement - Fraction project f2: General maintenance (GM) for CISPR 11 Ed.5.1 (2010)
A description is not available for this item.
Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement - Fraction project f2: General maintenance (GM) for CISPR 11 Ed.5.1 (2010)
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to...
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
This International Standard applies to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to...
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement - Supplement of CISPR 11 with the APD method and associated limits for assessment of fluctuating RF disturbances in the range above 1 GHz
A description is not available for this item.
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement - Supplement of CISPR 11 with emission requirements for Grid Connected Power Converters (GCPC)
To include table in Annex ZA, covering frequencies designated on a national basis in CENELEC countries for use as fundamental ISM frequencies.