scope:

This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v). The equipment, or parts thereof, may be intended for use in explosive atmospheres (see 4.1) and in mines susceptible to firedamp.

This document applies to equipment intended for monitoring oxygen deficiency and enrichment.

EXAMPLE Monitoring oxygen deficiency and/or enrichment includes:

- protection of human health and safety in potentially oxygen deficient atmospheres;

- fire protection by monitoring areas with reduced oxygen concentration;

- fire protection by monitoring oxygen concentrations exceeding that of normal ambient air.

This document also applies to equipment with an oxygen measuring function for explosion protection in the case of monitoring inertisation.

NOTE 1 Inertisation is an explosion protection technique where a potentially explosive atmosphere is purged with inert gas.

NOTE 2 Commonly used oxygen sensors in commercial equipment for industrial application are:

- electrochemical sensors (aqueous and solid electrolytes);

- paramagnetic sensors;

- zirconium dioxide sensors;

- tunable diode laser absorption spectroscopy sensors (TDLAS).

This document is applicable to equipment intended to measure reliably the oxygen concentration, to provide an indication, alarm or other output function, the purpose of which is to give a warning of a potential hazard and, in some cases, to initiate automatic or manual protective action(s), whenever the level exceeds or falls below an alarm set point.

This document is applicable to equipment, including integral sampling systems of aspirated equipment, intended to be used for commercial, industrial and non-residential safety applications.

This document does not apply to external sampling systems, or to equipment of laboratory or scientific type, or to medical equipment, or to equipment used only for process monitoring and/or control purposes. For equipment used for sensing the presence of multiple gases, this document applies only to the measurement of oxygen.

This document is also applicable to equipment using optical principles (e.g. TDLAS), where the optical transmitter and receiver or the optical transceiver (i.e. combined transmitter and receiver) and a suitable reflector are not located in a common enclosure. However, in this case it will be necessary to modify the test conditions described in Clause 5.3 and to introduce supplementary tests to Clause 5.4 of this document. Such supplementary tests will include alignment, beam block fault, long range operation. Guidance to appropriate modification of the test conditions and supplementary tests can be taken from EN 60079-29-4. Modifications of the test conditions as well as modified and supplementary tests are expected to be agreed between the manufacturer and test laboratory and identified and described in the test report.

Document History

June 1, 2023
Electrical equipment for the detection and measurement of oxygen - Performance requirements and test methods
A description is not available for this item.
CEI EN 50104
May 1, 2020
Electrical equipment for the detection and measurement of oxygen - Performance requirements and test methods
This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the...
January 1, 2011
Electrical apparatus for the detection and measurement of oxygen Performance requirements and test methods
La presente Norma specifica i requisiti generali di costruzione, di prova e di prestazione e descrive i metodi di prova per le apparecchiature portatili, mobili e fisse per la misura della...
September 1, 2005
Electrical apparatus for the detection and measurement of oxygen Performance requirements and test methods
La presente Variante introduce una nuova frase all'articolo 4.1. La presente Norma é annullata e sostituita dalla Nuova edizione, CEI EN 50104:2011-01 (CEI 31-29), tuttavia rimane applicabile fino al...
August 1, 2003
Electrical apparatus for the detection and measurement of oxygen - Performance requirements and test methods
La presente norma specifica i requisiti di prova e di prestazione per le apparecchiature portatili, mobili e fisse destinate alla misura di concentrazioni di ossigeno in miscela con i gas, con...
March 1, 1999
Costruzioni elettriche per la rilevazione e la misura di ossigeno - Requisiti di funzionamento e metodi di prova
La presente Norma fissa i requisiti di funzionamento ed i metodi di prova delle apparecchiature elettriche, destinate alla misura della concentrazione di ossigeno presente in una miscela gassosa....
June 1, 1996
Costruzioni elettriche per la rilevazione e la misura di ossigeno - Requisiti di funzionamento e metodi di prova
La presente Norma, destinata alle apparecchiature elettriche di uso commerciale ed industriale (portatili, mobili e fisse) per la misura della concentrazione di ossigeno presente nelle miscele...