NEN-EN-IEC 60947-4-1

Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters

active
Organization: NEN
Publication Date: 1 April 2019
Status: active
Page Count: 388
ICS Code (Other electrical accessories): 29.120.99
ICS Code (Low voltage switchgear and controlgear): 29.130.20
scope:

This part of IEC 60947 is applicable to the following equipment:

- electromechanical contactors and starters including motor protective switching device (MPSD);

- actuators of contactor relays;

- contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;

- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);

intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.

This document covers also the assessment procedure for electromechanical overload protection used in safety applications such as protecting a motor located in explosive atmosphere from the outside atmosphere: See Annex L.

This document does not apply to:

- starters for DC motors 1;

NOTE 1 The requirements for DC motor starters are under consideration for the next maintenance cycle.

- auxiliary contacts of contactors and contacts of contactor relays. These are covered by IEC 60947-5-1;

- starter used downstream to frequency drive1;

NOTE 2 Additional requirements for starter used downstream to frequency drive are under consideration for the next maintenance cycle.

- short-circuit protective device integrated within starters other than MPSDs. This is covered by IEC 60947-2 and IEC 60947-3;

- the use of the product with additional measure within explosive atmospheres. These are given in IEC 60079 series;

- embedded software design rules1;

- cyber security aspects. These are covered by IEC 62443 series.

The objective of this document is to state:

a) the characteristics of the equipment;

b) the conditions applicable to the equipment with reference to:

1) its operation and behaviour,

2) its dielectric properties,

3) its degree of protection,

4) its construction including safety measures against electric shock, fire hazard and mechanical hazard;

c) the tests intended for confirming that these conditions have been met, and the methods to be adopted for these tests;

d) the information to be given with the equipment or in the manufacturer's literature.

1 For this subject the manufacturer is responsible for taking additional safety measures.

Document History

Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
A description is not available for this item.
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
A description is not available for this item.
NEN-EN-IEC 60947-4-1
April 1, 2019
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
This part of IEC 60947 is applicable to the following equipment: – electromechanical contactors and starters including motor protective switching device (MPSD); – actuators of contactor relays; –...
October 1, 2012
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
A description is not available for this item.
May 1, 2010
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
This part of IEC 60947 applies to the types of equipment listed in 1.1.1 and 1.1.2 whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c....
October 1, 2005
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
A description is not available for this item.
February 1, 2003
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
A description is not available for this item.
April 1, 2001
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
Applies to the types of equipment listed in 1.1 and 1.2 whose main contacts are intended to be connected to circuits tha rated voltage of which does not exceed 1000 V a.c. or 1500 V d.c.

References

Advertisement