ASTM International - ASTM E2509-21

Standard Test Method for Temperature Calibration of Rheometers in Isothermal Mode

active
Buy Now
Organization: ASTM International
Publication Date: 1 October 2021
Status: active
Page Count: 4
ICS Code (Measurement of volume, mass, density, viscosity): 17.060
significance And Use:

5.1 Rheological properties such as viscosity and storage and loss modulus change rapidly with temperature. High quality determinations of these properties depend upon a stable and well-known... View More

scope:

1.1 This test method describes the temperature calibration or conformance of rheometers. The applicable temperature range is 0 °C to 80 °C however other ranges may be selected for the purpose at hand.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Document History

ASTM E2509-21
October 1, 2021
Standard Test Method for Temperature Calibration of Rheometers in Isothermal Mode
1.1 This test method describes the temperature calibration or conformance of rheometers. The applicable temperature range is 0 °C to 80 °C however other ranges may be selected for the purpose at...
August 1, 2014
Standard Test Method for Temperature Calibration of Rheometers in Isothermal Mode
1.1 This test method describes the temperature calibration or conformance of rheometers. The applicable temperature range is 0 to 80°C however other ranges may be selected for the purpose at hand....
February 1, 2008
Standard Test Method for Temperature Calibration of Rheometers in Isothermal Mode
1.1 This test method describes the temperature calibration or conformance of rheometers. The applicable temperature range is 0 to 80 C however other ranges may be selected for the purpose at hand....
Advertisement