NEN-EN 14180

Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing

pending
Organization: NEN
Publication Date: 1 April 2023
Status: pending
Page Count: 122
ICS Code (Sterilizing equipment): 11.080.10
scope:

This document specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure only.

These sterilizers are primarily used for the sterilization of heat labile medical devices in health care facilities.

This document specifies minimum requirements:

- for the performance and design of sterilizers intended to deliver an LTSF-process capable of sterilizing medical devices;

- for the equipment and controls of these sterilizers needed for operation, control and monitoring of the sterilization processes, and which can be used for validation of the sterilization process.

This document specifies further test equipment and test procedures used to verify conformance of the equipment design and performance specified by this document.

This document does not specify requirements and tests for decontamination systems for use in rooms, enclosures, or environmental spaces.

Document History

NEN-EN 14180
April 1, 2023
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
This document specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure...
June 1, 2014
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
NEN-EN 14180 specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure...
June 1, 2012
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
NEN-EN 14180 specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient pressure...
July 1, 2009
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
This European Standard specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient...
June 1, 2009
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
This European Standard specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient...
January 1, 2009
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
A description is not available for this item.
August 1, 2003
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
This European Standard specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient...
July 1, 2001
Sterilizers for medical purposes - Low temperature steam and formaldehyde sterilizers - Requirements and testing
This European Standard specifies requirements and tests for LTSF sterilizers, which use a mixture of low temperature steam and formaldehyde as sterilizing agent, and which are working below ambient...