CEI - EN 62116

Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters

inactive
Organization: CEI
Publication Date: 1 January 2012
Status: inactive
Page Count: 26
scope:

La presente Norma fornisce le linee guida per la prova dell'efficacia delle misure di prevenzione automatica dal funzionamento in isola, utilizzate in inverter di sistemi fotovoltaici collegati alla rete elettrica.
La procedura di prova ed i criteri descritti costituiscono le prescrizioni minime che consentono la ripetibilità della prova.
Gli inverter e gli altri tipi di dispositivi che soddisfano i requisiti descritti nel presente documento si possono considerare non suscettibili di funzionamento in isola, in altri termini, nel momento in cui essi individuano le condizioni di isola, cessano di alimentare la rete di distribuzione.
Questa Norma viene pubblicata dal CEI nella sola lingua inglese in quanto particolarmente mirata a settori specialistici.
La presente Norma recepisce il testo originale inglese della Pubblicazione IEC.
ATTENZIONE: La Norma contiene immagini e testo che, per una migliore lettura del contenuto, richiedono la stampa a colori.

Document History

December 1, 2015
Utility-interconnected photovoltaic inverters – Test procedure of islanding prevention measures
The purpose of this International Standard is to provide a test procedure to evaluate the performance of islanding prevention measures used with utility-interconnected PV systems. This standard...
December 1, 2014
Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters
The purpose of this International Standard is to provide a test procedure to evaluate the performance of islanding prevention measures used with utility-interconnected PV systems. This standard...
EN 62116
January 1, 2012
Test procedure of islanding prevention measures for utility-interconnected photovoltaic inverters
La presente Norma fornisce le linee guida per la prova dell’efficacia delle misure di prevenzione automatica dal funzionamento in isola, utilizzate in inverter di sistemi fotovoltaici collegati alla...