DSF/IEC 62578 TS ED. 2.0 - 22/211/DTS

Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz

inactive
Organization: DS
Status: inactive
Page Count: 102
scope:

IEC/TS 62578 describes the operation conditions and typical characteristics of Active Infeed Converters (AIC) of all technologies and topologies which can be connected between the electrical power supply system (lines) a.c.-side and a constant current or voltage type d.c.- side and which can convert electrical power (active and reactive) in both directions (generative or regenerative).

Applications with active infeed converters are commonly used with the d.c.-sides of adjustable speed power drive systems (PDS), uninterruptible power systems (UPS), active filters, photovoltaic systems, wind turbine systems etc. of all voltages and power sizes.

Active Infeed Converters are generally connected between the electrical power supply system (a.c.-side) and a current or voltage d.c.-side, with the objective to remove low frequency harmonics (e.g. less than 1 kHz) by synthesizing a sinusoidal a.c. current. Some of them can additionally compensate the pre-existing harmonic distortion of a given supply side voltage. They are moreover able to control the power factor of a power supply system section by moving the electrical power (active and reactive) in both directions (generative or regenerative), which enables energy saving in the system and stabilizes the power supply voltage or enables coupling of renewable energy sources or electrical energy storage devices to the supply.

A practical and analytical approach for emission values for AICs in power supply systems is given, which is based on the latest results for line impedance values between 2 kHz and 9 kHz and withstand capability of capacitors connected directly to the supply.

This results in recommendations for emission values below 150 kHz.

The following is excluded from the scope:

• Requirements for the design, development or further functionality of Active Infeed Applications

• Probability of interactions or influences of the AIC with other equipment caused by parasitic elements in an installation or caused by poor electronic design as well as their mitigations.

• "Overhead line" power supply systems as the vast majority of AICs is used in cable networks.

Document History

Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz
IEC/TS 62578 describes the operation conditions and typical characteristics of active infeed converters (AIC) of all technologies and topologies which can be connected between the electrical power...
Power electronics systems and equipment - Operations and characteristics of active infeed converter applications
This part of IEC 62578 TS describes the operation conditions and typical characteristics of Active Infeed Converters of all technologies and topologies which can be connected between the electrical...
DSF/IEC 62578 TS ED. 2.0 - 22/211/DTS
Power electronics systems and equipment - Operation conditions and characteristics of active infeed converter (AIC) applications including design recommendations for their emission values below 150 kHz
IEC/TS 62578 describes the operation conditions and typical characteristics of Active Infeed Converters (AIC) of all technologies and topologies which can be connected between the electrical power...